Schneider Electric Residual Current Circuit Breaker with Overload Protection, 6A Current Rating, 1-Pole, 30 mA Trip

Subtotaal (1 eenheid)*

€ 130,87

(excl. BTW)

€ 158,35

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 70 stuk(s) klaar voor verzending vanaf een andere locatie
  • Plus verzending 9 stuk(s) vanaf 14 augustus 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 130,87

*prijsindicatie

RS-stocknr.:
790-9260
Artikelnummer Distrelec:
304-02-118
Fabrikantnummer:
A9D11806
Fabrikant:
Schneider Electric
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Schneider Electric

Product Type

Residual Current Circuit Breaker with Overload Protection

Current Rating

6A

Range

Acti9

Number of Poles

1

Series

Acti9

Trip Sensitivity

30mA

Tripping Characteristics

Type C

Mount Type

DIN Rail

Rated AC Voltage

240V ac

Terminal Type

Screw

Earth Leakage Protection Type

Type A

Height

110mm

Depth

77.5mm

Width

18mm

Breaking Capacity

10kA

Reset Actuator Type

Toggle Switch

Tripping Mechanism

Thermal Magnetic

Application

Distribution

Standards/Approvals

IEC, RoHS

Schneider Electric Residual Current Circuit Breaker, 6A, 30mA Trip Sensitivity - Acti9 Series - A9D11806


Protect people and equipment from overload and short circuits with this residual circuit breaker from Schneider Electric. It eliminates the risk of prolonged and potentially serious shock for improved electrical safety in your workplace. A red indicator on the unit's front face gives you a quick visual indication of when it's tripped a faulty current. This device can be quickly snapped to a DIN rail and is suitable for industrial isolation applications.

Features & Benefits


• Green indicator strip to signal when the contacts are completely open and it's safe to work on the downstream circuit

• IP20 (ingress protection) rated insulation terminals indicates they're touch-proof and protected against objects larger than 12mm

• Stops leakage current from potentially causing an electrical fire for improved safety levels

Applications


• Commercial lighting systems

• Industrial process control

• Residential electrical control cabinets

What is overcurrent?


Overcurrent is a type of electrical fault that's caused by either an overload or short circuit in an electrical system. It's possible to overload a circuit by connecting too many electrical devices and exceeding the power capacity of a cable. Short circuits occur when there's insufficient resistance in a circuit.