ABB Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 4-Pole, 30 mA Trip Sensitivity, Type
- RS-stocknr.:
- 237-5098
- Fabrikantnummer:
- 2CSR254001R1164
- Fabrikant:
- ABB
Subtotaal (1 eenheid)*
€ 195,04
(excl. BTW)
€ 236,00
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Tijdelijk niet op voorraad
- Verzending vanaf 22 januari 2027
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 195,04 |
*prijsindicatie
- RS-stocknr.:
- 237-5098
- Fabrikantnummer:
- 2CSR254001R1164
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Current Rating | 16A | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Series | DS200 | |
| Number of Poles | 4 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 400V ac | |
| Terminal Type | Busbar | |
| Earth Leakage Protection Type | AC | |
| Width | 69mm | |
| Height | 93mm | |
| Depth | 93mm | |
| Reset Actuator Type | Lever | |
| Application | Short Circuit Protection, Residential, Overload Protection | |
| Breaking Capacity | 6kA | |
| Standards/Approvals | CE | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Current Rating 16A | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Series DS200 | ||
Number of Poles 4 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 400V ac | ||
Terminal Type Busbar | ||
Earth Leakage Protection Type AC | ||
Width 69mm | ||
Height 93mm | ||
Depth 93mm | ||
Reset Actuator Type Lever | ||
Application Short Circuit Protection, Residential, Overload Protection | ||
Breaking Capacity 6kA | ||
Standards/Approvals CE | ||
- Land van herkomst:
- IT
ABB DS200 Series RCBO, 16A, 4 Poles - 2CSR254001R1164
This RCBO from ABB with a current rating of 16A features a 4 pole setup and Type C tripping characteristics. The product offers reliable protection against overload and short circuit currents, making it a valuable addition to any electrical system.
Features & Benefits
• Designed for protection against overload and short-circuit currents
• Offers additional protection against indirect and direct contacts
• Tripping characteristics meet Type C standards for efficient performance
• Features a 4 pole setup for comprehensive circuit protection
• Rated AC voltage of 400V ensures compatibility with various systems
Applications
• Suitable for applications requiring reliable circuit protection against various electrical faults
• Can be used for installations where protection against overload and short circuits is crucial
Can it protect against both overload and short-circuit currents?
Yes, the ABB RCBO is designed to offer protection against both overload and short-circuit currents.
Will it provide additional protection against direct contacts?
Yes, it includes features for protection against direct contacts as well.
Is it suitable for use in industrial settings?
Yes, the RCBO is reliable for industrial applications requiring comprehensive circuit protection.
Gerelateerde Links
- Contactum Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- Hager Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- Hager Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 3-Pole, 300 mA Trip Sensitivity,
- Siemens Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 2-Pole, 30 mA Trip Sensitivity,
- Siemens Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- Europa Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 2-Pole, 30 mA Trip Sensitivity,
- ABB Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- Siemens Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 10 mA Trip Sensitivity,