ABB RCBO, 40A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type C
- RS-stocknr.:
- 237-3390
- Fabrikantnummer:
- 2CSR252001R1404
- Fabrikant:
- ABB
Subtotaal (1 eenheid)*
€ 176,54
(excl. BTW)
€ 213,61
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Tijdelijk niet op voorraad
- Verzending vanaf 03 februari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 176,54 |
*prijsindicatie
- RS-stocknr.:
- 237-3390
- Fabrikantnummer:
- 2CSR252001R1404
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Current Rating | 40A | |
| Number of Poles | 2 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Circuit Breaker Type | RCBO | |
| Series | DS200 | |
| Rated AC Voltage | 230V | |
| Breaking Capacity at Maximum Voltage Rating | 6 kA | |
| Overall Depth | 69mm | |
| Overall Width | 70mm | |
| Special Features | Short Circuit Protection | |
| Overall Length | 69mm | |
| Break Time | Instantaneous | |
| Reset Actuator Type | Toggle Switch | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Current Rating 40A | ||
Number of Poles 2 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Circuit Breaker Type RCBO | ||
Series DS200 | ||
Rated AC Voltage 230V | ||
Breaking Capacity at Maximum Voltage Rating 6 kA | ||
Overall Depth 69mm | ||
Overall Width 70mm | ||
Special Features Short Circuit Protection | ||
Overall Length 69mm | ||
Break Time Instantaneous | ||
Reset Actuator Type Toggle Switch | ||
- Land van herkomst:
- IT
ABB DS200 Series RCBO, 40A Current Rating, 30mA Trip Sensitivity - 2CSR252001R1404 D. DS202 AC-C40/0.03
This RCBO from the DS200 series is designed for effective overload and short-circuit protection in electrical circuits. Delivering high performance with a rated current of 40A and a trip sensitivity of 30mA, it is ideal for various applications in the electrical and automation sectors. With dimensions of 69mm x 70mm x 69mm, this compact device fits seamlessly into standard installations.
Features & Benefits
• Provides short circuit protection, safeguarding connected devices
• Instantaneous tripping ensures rapid response to faults
• Type C circuit breaker allows for higher inrush currents
• 2 pole design supports dual-phase circuits
• Rated breaking capacity of 6kA protects against circuit damage
• Designed for use in a wide temperature range from -25 to +55°C
• Instantaneous tripping ensures rapid response to faults
• Type C circuit breaker allows for higher inrush currents
• 2 pole design supports dual-phase circuits
• Rated breaking capacity of 6kA protects against circuit damage
• Designed for use in a wide temperature range from -25 to +55°C
Applications
• Used for protecting residential and commercial electrical installations
• Ideal for application in circuit protection panels
• Suited for installation in industrial machinery and distribution boards
• Used with sensitive electronic equipment requiring reliable protection
• Ideal for application in circuit protection panels
• Suited for installation in industrial machinery and distribution boards
• Used with sensitive electronic equipment requiring reliable protection
What type of environments can this RCBO operate in?
It can operate in environments with temperatures ranging from -25°C to +55°C, suitable for various indoor electrical installations and challenges.
How does the instantaneous tripping feature enhance safety?
The instantaneous tripping mechanism quickly cuts off power during fault conditions, preventing potential fire hazards and equipment damage.
What makes the Type C circuit breaker suitable for my applications?
Type C circuit breakers are designed to handle moderate inrush currents, making them ideal for inductive loads such as motors and transformers.
Can this device be used in both residential and commercial settings?
Yes, it is versatile enough to be used in both residential circuits and larger commercial electrical systems for effective protection.
How does the breaking capacity of 6kA contribute to safety?
A breaking capacity of 6kA ensures that the device can effectively interrupt fault currents without sustaining damage, promoting safety for both equipment and users.
Gerelateerde Links
- ABB RCBO, 40A Current Rating, 2P Poles, 30mA Trip Sensitivity
- Europa RCBO, 40A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type C
- Siemens RCBO, 40A Current Rating, 2P Poles, 30mA Trip Sensitivity, Sentron Range
- Europa RCBO, 40A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type A, EUBLMC Range
- Siemens RCBO, 40A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type C, Sentron Range
- Siemens RCBO, 40A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type B, Sentron Range
- ABB RCBO, 40A Current Rating, 2P Poles, 30mA Trip Sensitivity, System Pro M Compact Range
- ABB RCBO, 6A Current Rating, 2P Poles, 30mA Trip Sensitivity