Schneider Electric RCBO, 16A Current Rating, 3P Poles, 30mA Trip Sensitivity, Type C, Acti9 Range
- RS-stocknr.:
- 212-247
- Fabrikantnummer:
- A9D17316
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 217,74
(excl. BTW)
€ 263,47
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- Plus verzending 1 stuk(s) vanaf 08 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 217,74 |
*prijsindicatie
- RS-stocknr.:
- 212-247
- Fabrikantnummer:
- A9D17316
- Fabrikant:
- Schneider Electric
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Current Rating | 16A | |
| Number of Poles | 3 | |
| Range | Acti9 | |
| Trip Sensitivity | 30mA | |
| Series | Acti9 iC60 | |
| Tripping Characteristics | Type C | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Current Rating 16A | ||
Number of Poles 3 | ||
Range Acti9 | ||
Trip Sensitivity 30mA | ||
Series Acti9 iC60 | ||
Tripping Characteristics Type C | ||
- Land van herkomst:
- PT
The Schneider Electric Residual Current Breaker with overcurrent protection is designed for AC networks. It has a rated current of 16 A and features thermal-magnetic trip unit technology for overcurrent protection. The device operates with a rated operational voltage of 230 to 240 V AC at 50 Hz and has a rated insulation voltage of 400 V AC at 50 Hz. It uses a toggle control type for easy operation and switching.
Clip on mounting
20000 cycles of mechanical durability
IP40 rated for modular enclosure conforming to IEC 60529
20000 cycles of mechanical durability
IP40 rated for modular enclosure conforming to IEC 60529
Gerelateerde Links
- Schneider Electric RCBO, 16A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range
- Schneider Electric RCBO, 16A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Acti9 Range
- Schneider Electric RCBO, 20A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range
- Schneider Electric RCBO, 40A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range
- Schneider Electric RCBO, 6A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range
- Schneider Electric RCBO, 10A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range
- Schneider Electric RCBO, 25A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range
- Schneider Electric RCBO, 16A Current Rating, 4P Poles, 30mA Trip Sensitivity, Type AC, Acti9 Range
