Schneider Electric Residual Current Circuit Breaker with Overload Protection, 25A Current Rating, 4-Pole, 30 mA Trip
- RS-stocknr.:
- 130-866
- Fabrikantnummer:
- A9D77425
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 764,67
(excl. BTW)
€ 925,25
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Op voorraad
- Plus verzending 1 stuk(s) vanaf 25 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 764,67 |
*prijsindicatie
- RS-stocknr.:
- 130-866
- Fabrikantnummer:
- A9D77425
- Fabrikant:
- Schneider Electric
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Current Rating | 25A | |
| Number of Poles | 4 | |
| Series | Acti9 | |
| Range | Acti9 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Mount Type | DIN Rail | |
| Rated AC Voltage | 415V ac | |
| Terminal Type | Tunnel | |
| Depth | 78mm | |
| Width | 72mm | |
| Height | 86mm | |
| Reset Actuator Type | Toggle | |
| Breaking Capacity | 6000A | |
| Application | Distribution | |
| Standards/Approvals | EN/IEC 60947-2, EN/IEC 61009-2-1 | |
| Tripping Mechanism | Thermal Magnetic | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Current Rating 25A | ||
Number of Poles 4 | ||
Series Acti9 | ||
Range Acti9 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Mount Type DIN Rail | ||
Rated AC Voltage 415V ac | ||
Terminal Type Tunnel | ||
Depth 78mm | ||
Width 72mm | ||
Height 86mm | ||
Reset Actuator Type Toggle | ||
Breaking Capacity 6000A | ||
Application Distribution | ||
Standards/Approvals EN/IEC 60947-2, EN/IEC 61009-2-1 | ||
Tripping Mechanism Thermal Magnetic | ||
- Land van herkomst:
- PT
The Schneider Electric Acti9 iC60 RCBO residual current breaker with overcurrent protection. It offers high breaking capacity and sensitivity. It is designed for distribution applications and provides voltage independent tripping technology for enhanced safety.
4P poles configuration for comprehensive protection
30mA earth-leakage sensitivity for quick response
Thermal-magnetic trip unit technology for reliable performance
Toggle control type for easy operation
DIN rail mounting support for flexibility
Gerelateerde Links
- Siemens Residual Current Circuit Breaker with Overload Protection, 25A Current Rating, 2-Pole, 30 mA Trip Sensitivity,
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 25A Current Rating, 1-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 25A Current Rating, 4-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 25A Current Rating, 1-Pole, 300 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 25A Current Rating, 1-Pole, 25000 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 25A Current Rating, 3-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 25A Current Rating, 4-Pole, 300 mA Trip
- Contactum Residual Current Circuit Breaker with Overload Protection, 25A Current Rating, 1-Pole, 30 mA Trip Sensitivity,