Schneider Electric IMDIM15H, Power Factor Controller 230V ac
- RS-stocknr.:
- 345-348
- Fabrikantnummer:
- IMDIM15H
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 7.175,25
(excl. BTW)
€ 8.682,05
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Voorradig bij de fabrikant
- Klaar voor verzending vanaf 10 augustus 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 7.175,25 |
*prijsindicatie
- RS-stocknr.:
- 345-348
- Fabrikantnummer:
- IMDIM15H
- Fabrikant:
- Schneider Electric
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Product Type | Power Factor Controller | |
| Maximum Source Current | 0.2mA | |
| Mount Type | Flush | |
| Minimum Supply Voltage | 110V | |
| Maximum Supply Voltage | 230V ac | |
| Minimum Operating Temperature | -25°C | |
| Standards/Approvals | IEC 61326-2-4, CE, EAC, IEC 60364-7-710, BV, DNV, IEC 61010-1, IEC 61557-8 | |
| Height | 110mm | |
| Length | 59mm | |
| Maximum Operating Temperature | 55°C | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Product Type Power Factor Controller | ||
Maximum Source Current 0.2mA | ||
Mount Type Flush | ||
Minimum Supply Voltage 110V | ||
Maximum Supply Voltage 230V ac | ||
Minimum Operating Temperature -25°C | ||
Standards/Approvals IEC 61326-2-4, CE, EAC, IEC 60364-7-710, BV, DNV, IEC 61010-1, IEC 61557-8 | ||
Height 110mm | ||
Length 59mm | ||
Maximum Operating Temperature 55°C | ||
- Land van herkomst:
- IN
The Schneider Electric Insulation monitoring device is dedicated to monitoring AC, DC and ACDC medical IT systems. It measures the system insulation resistance by injecting a low frequency AC current between the network and ground. Configuration will be set in accordance to medical standards, from the front of the device, through the HMI screen. Setting are related to insulation alarm thresholds from 50 kilohms to 500 kilohms, and Transformer overheat and overload alarms. It monitors networks up to 230VAC, 230VDC, in medical IT architecture, and well as the medical IT transformer.
RoHS compliant
Mercury free
IP20 and IP52 protection rated
Overvoltage category III
Gerelateerde Links
- Schneider Electric EVCP120D5N12, Power Factor Controller 60 Hz 480V ac
- Schneider Electric EVCP200D5N12, Power Factor Controller 60 Hz 480V ac
- Schneider Electric VPL06N, Power Factor Pre-Regulator Circuit 550V ac
- RS PRO, Power Factor Controller 550V ac
- Schneider Electric VPL12N, Power Factor Pre-Regulator Circuit 60 Hz 550V ac
- Schneider Electric Power Factor Correction Capacitor 25 kvar
- Schneider Electric Power Factor Correction Capacitor 350 kvar
- Schneider Electric Power Factor Correction Capacitor 175 kvar