Schneider Electric Twido Series Logic Module, 100 → 240 V ac Supply, Relay, Transistor Output, 24-Input, Sink,

Niet beschikbaar
RS heeft dit product niet meer op voorraad.
RS-stocknr.:
528-8643
Fabrikantnummer:
TWDLCAE40DRF
Fabrikant:
Schneider Electric
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Schneider Electric

Manufacturer Series

Twido

Number of Inputs

24

Output Type

Relay, Transistor

Supply Voltage

100 → 240 V ac

Input Type

Sink, Source

Number of Outputs

16

Network Type

Ethernet

Output Current

2 A

Programming Language Used

Ladder Logic

Mounting Type

DIN Rail

Width

157mm

Length

90mm

Depth

70mm

Program Capacity

3000 Instructions

Display Included

Yes

Dimensions

90 x 157 x 70 mm

Minimum Operating Temperature

0°C

Programming Interface

Computer, HMI

Number of Communication Ports

1

Maximum Operating Temperature

+50°C

Communication Port Type

RS485

N.v.t.

Land van herkomst:
CN

Twido Compact Controller


24 Vdc inputs
Isolated outputs
100base-TX ethernet via RJ45
Output rating for relay outputs: 2A@ 250Vac
Output rating for transistor outputs: 0.3A@ 24Vdc
Dimensions: H90 x W80 x D70mm (10 and 16 I/O)
H90 x W95 x D70mm (24 I/O)
H90 x W157 x D70mm (40 I/O)


Schneider Electric Twido Base Units - Additional Info:


Twido programmable controller from Telemecanique providing flexible automation solutions for the control systems. Designed to be user-friendly and flexible, with powerful control functions.


Small footprint reduces panel size for applications where space is limited
Flexible cabling choices (removable screw terminal blocks and spring-type connectors for expandable units), allowing quick and easy wiring
Suitable for applications requiring 10 - 264 I/O points
Compact controllers available with 10, 16, 24 or 40 I/O points
Each controller has an RS-485 programming port and stock no. 528-8643 also has an RJ45 ethernet port
Modular controllers available with 20 or 40 I/O points
All products in the Twido range meet the standards of the following regulatory agencies: IEC61131-2, UL1604/CSA C22.2 No.213 (class 1, division 2, groups A, B, C, D), CE and TÜV


Maximum I/O configuration


In order to connect all digital Input/Output modules and analogue Input/Output modules to base controllers, units should be built on DIN rails starting from the right-hand side of the bases, according to the following rules:


10 and 16 I/O compact bases cannot be expanded
24 I/O compact bases, can accommodate up to a maximum of 4 modules
40 I/O compact bases, can accommodate up to a maximum of 7 modules
20 I/O modular bases, can accommodate up to a maximum of 4 modules
40 I/O modular bases, can accommodate up to a maximum of 7 modules

Gerelateerde Links