RS PRO 9 V ac 2 Output Through Hole PCB Transformer, CE, RoHS, UKCA 12 VA
- RS-stocknr.:
- 504-723
- Fabrikant:
- RS PRO
Bulkkorting beschikbaar
Subtotaal (1 eenheid)*
€ 32,56
(excl. BTW)
€ 39,40
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Laatste voorraad RS
- Laatste 4 stuk(s), klaar voor verzending vanaf een andere locatie
Aantal stuks | Per stuk |
|---|---|
| 1 - 4 | € 32,56 |
| 5 - 9 | € 30,27 |
| 10 - 24 | € 28,32 |
| 25 + | € 26,37 |
*prijsindicatie
- RS-stocknr.:
- 504-723
- Fabrikant:
- RS PRO
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | RS PRO | |
| Product Type | PCB Transformer | |
| Secondary Voltage | 9 V ac | |
| Primary Voltage | 230 V ac | |
| Number of Outputs | 2 | |
| Length | 54mm | |
| Width | 45 mm | |
| Power | 12VA | |
| Depth | 41mm | |
| Weight | 400g | |
| Mount Type | Through Hole | |
| Isolation Voltage | 4kVrms | |
| Winding Type | Dual Secondary, Single Primary | |
| Maximum Operating Temperature | 130°C | |
| Efficiency | 82% | |
| Minimum Operating Frequency | 50Hz | |
| Maximum Operating Frequency | 60Hz | |
| Standards/Approvals | CE, RoHS, UKCA | |
| Alles selecteren | ||
|---|---|---|
Merk RS PRO | ||
Product Type PCB Transformer | ||
Secondary Voltage 9 V ac | ||
Primary Voltage 230 V ac | ||
Number of Outputs 2 | ||
Length 54mm | ||
Width 45 mm | ||
Power 12VA | ||
Depth 41mm | ||
Weight 400g | ||
Mount Type Through Hole | ||
Isolation Voltage 4kVrms | ||
Winding Type Dual Secondary, Single Primary | ||
Maximum Operating Temperature 130°C | ||
Efficiency 82% | ||
Minimum Operating Frequency 50Hz | ||
Maximum Operating Frequency 60Hz | ||
Standards/Approvals CE, RoHS, UKCA | ||
- Land van herkomst:
- PL

PCB Mounting, Flame Retardant Transformer with Thermal Fuse
Thermal fuse in primary providing overload and short circuit protection
Flame retardant materials to UL94-V0
Fully shrouded windings
Extra pins for secure board mounting
Designed and tested in accordance with EN 61558 (EN 60742) EN 60950
Open Frame - Laminated
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.
Double section metric bobbin construction
Full varnish impregnation
Standards
EN 61558 (EN 60742); EN 60950
Gerelateerde Links
- RS PRO 9V ac 2 Output Through Hole PCB Transformer, 12VA
- RS PRO 24V ac 2 Output Through Hole PCB Transformer, 12VA
- RS PRO 15V ac 2 Output Through Hole PCB Transformer, 12VA
- RS PRO 12V ac 2 Output Through Hole PCB Transformer, 12VA
- RS PRO 6V ac 2 Output Through Hole PCB Transformer, 12VA
- RS PRO 20V ac 2 Output Through Hole PCB Transformer, 12VA
- RS PRO 9V ac 2 Output Through Hole PCB Transformer, 3VA
- RS PRO 9V ac 2 Output Through Hole PCB Transformer, 6VA