Martindale EPAT2100 PAT Tester, Class I, Class II Test Type With UKAS Calibration
- RS-stocknr.:
- 711-8975
- Fabrikantnummer:
- RSEPAT2100
- Fabrikant:
- Martindale
Subtotaal (1 eenheid)*
€ 1.182,50
(excl. BTW)
€ 1.430,82
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Tijdelijk niet op voorraad
- Verzending 3 stuk(s) vanaf 06 februari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.182,50 |
*prijsindicatie
- RS-stocknr.:
- 711-8975
- Fabrikantnummer:
- RSEPAT2100
- Fabrikant:
- Martindale
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Martindale | |
| Tester Type | Dual Voltage PAT | |
| Test Type | Class I, Class II | |
| Testing Method | Manual | |
| Calibrated | UKAS | |
| Flash Test | Yes | |
| Plug Type | Type G - British 3-pin | |
| Model Number p | EPAT2100 | |
| Power Source | Mains | |
| Weight | 4.6kg | |
| Height | 144mm | |
| Length | 330mm | |
| Maximum Operating Temperature | +35°C | |
| Maximum Supply Voltage | 240V | |
| Minimum Supply Voltage | 110V | |
| Width | 263mm | |
| Minimum Operating Temperature | 0°C | |
| Alles selecteren | ||
|---|---|---|
Merk Martindale | ||
Tester Type Dual Voltage PAT | ||
Test Type Class I, Class II | ||
Testing Method Manual | ||
Calibrated UKAS | ||
Flash Test Yes | ||
Plug Type Type G - British 3-pin | ||
Model Number p EPAT2100 | ||
Power Source Mains | ||
Weight 4.6kg | ||
Height 144mm | ||
Length 330mm | ||
Maximum Operating Temperature +35°C | ||
Maximum Supply Voltage 240V | ||
Minimum Supply Voltage 110V | ||
Width 263mm | ||
Minimum Operating Temperature 0°C | ||
N.v.t.
- Land van herkomst:
- PH
Professional Manual PAT Tester Martindale EPAT2100
The EasyPAT 2100 is a high speed, fully specified dual voltage PAT tester which is ideal for contractors and workshops. With a simple push button test selection and an excellent test result display, it is an excellent choice in manual PAT testers. The flash test is particularly useful for repairs.
Features include:
100mA DC, 8A AC or 25A AC earth bond tests selectable with a simple rocker switch
Built-in extension lead tester
Dual Voltage Operation - capable of testing both 110V and 240V appliances, making it ideal for a wide range of equipment, including IT devices and power tools.
Comprehensive Testing - performs essential PAT tests such as earth bond, insulation, run current, run leakage, and flash testing, ensuring thorough safety checks.
User-Friendly Design - the integrated LCD screen provides clear test results, while the straightforward operation makes it accessible for both novice and experienced users.
Portability and Protection - the rugged case not only protects the tester but also offers ample storage for accessories, ensuring everything you need is at hand.
Display - 0.7", 2 digit LCD with annunciators indicating supply voltage and units of measurement in use
Flash Gun - Safety gun for flash testing
Built-in extension lead tester
Dual Voltage Operation - capable of testing both 110V and 240V appliances, making it ideal for a wide range of equipment, including IT devices and power tools.
Comprehensive Testing - performs essential PAT tests such as earth bond, insulation, run current, run leakage, and flash testing, ensuring thorough safety checks.
User-Friendly Design - the integrated LCD screen provides clear test results, while the straightforward operation makes it accessible for both novice and experienced users.
Portability and Protection - the rugged case not only protects the tester but also offers ample storage for accessories, ensuring everything you need is at hand.
Display - 0.7", 2 digit LCD with annunciators indicating supply voltage and units of measurement in use
Flash Gun - Safety gun for flash testing
Applications:
The Martindale EasyPAT 2100 is designed for a variety of applications, making it a versatile tool for professionals in different fields. Here are some of its primary applications:
Onsite PAT Testing - ensuring that electrical appliances are safe to use in various environments such as offices, schools, hospitals, and construction sites.
Workshop Applications - to test tools and equipment, ensuring they meet safety standards before being used in daily operations. This helps maintain a safe working environment and reduces the risk of electrical hazards.
IT Equipment Testing - including computers, servers, and peripherals. Its dual voltage capability allows it to handle both 110V and 240V appliances, making it versatile for different types of IT infrastructure.
Class I & Class II Appliance Testing
Extension & IEC Lead Testing
Comprehensive Safety Checks - with its ability to perform high and low current earth bond tests, insulation tests, run current tests, and leakage tests, the EasyPAT 2100 provides comprehensive safety checks for electrical appliances
Onsite PAT Testing - ensuring that electrical appliances are safe to use in various environments such as offices, schools, hospitals, and construction sites.
Workshop Applications - to test tools and equipment, ensuring they meet safety standards before being used in daily operations. This helps maintain a safe working environment and reduces the risk of electrical hazards.
IT Equipment Testing - including computers, servers, and peripherals. Its dual voltage capability allows it to handle both 110V and 240V appliances, making it versatile for different types of IT infrastructure.
Class I & Class II Appliance Testing
Extension & IEC Lead Testing
Comprehensive Safety Checks - with its ability to perform high and low current earth bond tests, insulation tests, run current tests, and leakage tests, the EasyPAT 2100 provides comprehensive safety checks for electrical appliances
Gerelateerde Links
- Martindale EPAT2100 PAT Tester, Class I, Class II Test Type With RS Calibration
- Martindale EPAT2100 PAT Tester, Class I, Class II Test Type
- Martindale MPATPLUS PAT Tester, Class I, Class II Test Type With UKAS Calibration
- Martindale HPAT600/2 PAT Tester, Class I, Class II Test Type With UKAS Calibration
- Martindale EPAT1600 PAT Tester, Class I, Class II, Class IT Test Type With UKAS Calibration
- Martindale MPATPLUS PAT Tester, Class I, Class II Test Type With RS Calibration
- Martindale HPAT600/2 PAT Tester, Class I, Class II Test Type With RS Calibration
- Martindale EPAT1600 PAT Tester, Class I, Class II, Class IT Test Type With RS Calibration