PicoScope 3000 Series, 70 MHz PC Based Oscilloscope 4-Channel
- RS-stocknr.:
- 846-3421
- Artikelnummer Distrelec:
- 300-18-071
- Fabrikantnummer:
- PicoScope 3404D
- Fabrikant:
- Pico Technology
Momenteel niet beschikbaar
We weten niet of dit item nog op voorraad komt, RS is van plan dit binnenkort uit ons assortiment te halen.
- RS-stocknr.:
- 846-3421
- Artikelnummer Distrelec:
- 300-18-071
- Fabrikantnummer:
- PicoScope 3404D
- Fabrikant:
- Pico Technology
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Pico Technology | |
| Product Type | Oscilloscope | |
| Bandwidth | 70MHz | |
| Number of Channels | 4 | |
| Model Number | PicoScope 3404D | |
| Oscilloscope Type | PC Based | |
| Interface Type | CAN, IIC, LIN, RS232, SPI, UART, USB | |
| Series | PicoScope 3000 | |
| Standards/Approvals | RoHS, WEEE | |
| Width | 170mm | |
| Length | 190mm | |
| Height | 40mm | |
| Minimum Time Base | 1ns/div | |
| Maximum Time Base | 5000s/div | |
| Rise Time | 5ns | |
| Maximum Vertical Sensitivity | 4V/div | |
| Minimum Vertical Sensitivity | 4mV/div | |
| Vertical Resolution | 8 bit | |
| Power Source | USB | |
| Alles selecteren | ||
|---|---|---|
Merk Pico Technology | ||
Product Type Oscilloscope | ||
Bandwidth 70MHz | ||
Number of Channels 4 | ||
Model Number PicoScope 3404D | ||
Oscilloscope Type PC Based | ||
Interface Type CAN, IIC, LIN, RS232, SPI, UART, USB | ||
Series PicoScope 3000 | ||
Standards/Approvals RoHS, WEEE | ||
Width 170mm | ||
Length 190mm | ||
Height 40mm | ||
Minimum Time Base 1ns/div | ||
Maximum Time Base 5000s/div | ||
Rise Time 5ns | ||
Maximum Vertical Sensitivity 4V/div | ||
Minimum Vertical Sensitivity 4mV/div | ||
Vertical Resolution 8 bit | ||
Power Source USB | ||
- Land van herkomst:
- GB
PicoScope 3000 Series Oscilloscope, 70MHz Bandwidth, 4 Channels - PicoScope 3404D
This oscilloscope is a PC-connected diagnostic instrument designed for waveform capture and analysis via USB power. It operates as a multi-channel measurement tool suitable for electrical testing and signal inspection in laboratory and field settings. The instrument supports serial and automotive communications and provides configurable timebase ranges for both fast and extended observations.
Features and Benefits:
• 70MHz bandwidth delivers detailed analogue signal visibility
• 5ns rise time captures Rapid transient events
• 8-bit vertical resolution balances speed and data size
• 4mV/div minimum sensitivity resolves small amplitude signals
• 5000s/div maximum timebase enables long-duration monitoring
• 5ns rise time captures Rapid transient events
• 8-bit vertical resolution balances speed and data size
• 4mV/div minimum sensitivity resolves small amplitude signals
• 5000s/div maximum timebase enables long-duration monitoring
Applications
• Suitable for automotive diagnostics using LIN and CAN networks
• Ideal for embedded systems debugging over SPI and I2C buses
• Used with serial devices employing RS232 and UART protocols
• Can be used for laboratory signal capture via USB PC Interface
• Suitable for field testing where portable USB power is available
• Ideal for embedded systems debugging over SPI and I2C buses
• Used with serial devices employing RS232 and UART protocols
• Can be used for laboratory signal capture via USB PC Interface
• Suitable for field testing where portable USB power is available
What interfaces are available for connecting to external devices?
It provides CAN, I2C, LIN, RS232, SPI, UART and USB connections for diverse signalling standards.
What are the timebase extremes and how do they affect measurements?
The minimum timebase of 1ns/div permits high-speed capture while the maximum of 5000s/div allows long-term signal logging.
How is the instrument powered during operation?
The unit is powered via the USB connection, eliminating a separate mains supply.
What vertical measurement range can be expected on channels?
The vertical sensitivity ranges from 4mV/div up to 4V/div to accommodate both low- and higher-amplitude signals.
Supplied with
Switchable x1/x10 probes (1 per analog channel) in carrying case, Quick Start guide, software and reference CD, USB cables, power adaptor (with 4 analog channel models only)
Gerelateerde Links
- Pico Technology PicoScope 3000 Series, 70 MHz PC Based Oscilloscope 4-Channel
- Pico Technology PicoScope 3000 Series, 70 MHz PC Based Oscilloscope 4-Channel, RSCAL
- Pico Technology PicoScope 3000 Series, 70 MHz PC Based Oscilloscope 4-Channel, UKAS
- Pico Technology PicoScope 3000 Series, 70 MHz PC Based Oscilloscope 2-Channel
- Pico Technology PicoScope 3000 Series, 70 MHz PC Based Oscilloscope 16-Channel
- Pico Technology PicoScope 3000 Series, 70 MHz PC Based Oscilloscope 2-Channel, RSCAL
- Pico Technology PicoScope 3000 Series, 70 MHz PC Based Oscilloscope 2-Channel, UKAS
- Pico Technology PicoScope 3000 Series, 50 MHz PC Based Oscilloscope 4-Channel

