Fluke 3000 FC 3000 FC Digital Digital Multimeter True RMS, 400 mA ac, 400 mA dc, 1 kV ac
- RS-stocknr.:
- 811-1316
- Artikelnummer Distrelec:
- 110-83-815
- Fabrikantnummer:
- FLK-3000 FC
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 454,00
(excl. BTW)
€ 549,34
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
- Plus verzending 1 stuk(s) vanaf 11 mei 2026
- Plus verzending 32 stuk(s) vanaf 11 mei 2026
- Plus verzending 3 stuk(s) vanaf 15 mei 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 454,00 |
*prijsindicatie
- RS-stocknr.:
- 811-1316
- Artikelnummer Distrelec:
- 110-83-815
- Fabrikantnummer:
- FLK-3000 FC
- Fabrikant:
- Fluke
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Multimeter Type | Digital | |
| Product Type | Multimeter | |
| Display Type | Digital | |
| Resistance Resolution | 100mΩ | |
| Model Number | 3000 FC | |
| Functions Measured | AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature | |
| Maximum AC Voltage Measurement | 1kV ac | |
| Maximum AC Current Measurement | 400mA ac | |
| Maximum Resistance Measurement | 50mΩ | |
| Maximum DC Current Measurement | 400mA dc | |
| Maximum DC Voltage Measurement | 1kV dc | |
| True RMS | Yes | |
| AC Current Accuracy | ±1.5 % | |
| DC Voltage Accuracy | ±0.09 % | |
| DC Current Accuracy | ±0.5 % | |
| AC Voltage Accuracy | ± 1 % + 3 | |
| DC Current Resolution | 0.01mA dc | |
| AC Current Resolution | 0.01mA ac | |
| AC Voltage Resolution | 0.1mV ac | |
| DC Voltage Resolution | 0.1 mV dc | |
| Maximum Frequency | 99.99kHz | |
| Minimum Operating Temperature | -10°C | |
| Resistance Measurement Accuracy | ±0.5 % rdg | |
| Battery Life | 250h | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | No | |
| Series | 3000 FC | |
| Width | 93mm | |
| Length | 207mm | |
| Height | 47.5mm | |
| Weight | 340g | |
| Safety Category Level | CAT III, CAT IV | |
| Battery Type | AA Alkaline | |
| Safety Category Voltage | 1000V | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Multimeter Type Digital | ||
Product Type Multimeter | ||
Display Type Digital | ||
Resistance Resolution 100mΩ | ||
Model Number 3000 FC | ||
Functions Measured AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature | ||
Maximum AC Voltage Measurement 1kV ac | ||
Maximum AC Current Measurement 400mA ac | ||
Maximum Resistance Measurement 50mΩ | ||
Maximum DC Current Measurement 400mA dc | ||
Maximum DC Voltage Measurement 1kV dc | ||
True RMS Yes | ||
AC Current Accuracy ±1.5 % | ||
DC Voltage Accuracy ±0.09 % | ||
DC Current Accuracy ±0.5 % | ||
AC Voltage Accuracy ± 1 % + 3 | ||
DC Current Resolution 0.01mA dc | ||
AC Current Resolution 0.01mA ac | ||
AC Voltage Resolution 0.1mV ac | ||
DC Voltage Resolution 0.1 mV dc | ||
Maximum Frequency 99.99kHz | ||
Minimum Operating Temperature -10°C | ||
Resistance Measurement Accuracy ±0.5 % rdg | ||
Battery Life 250h | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals No | ||
Series 3000 FC | ||
Width 93mm | ||
Length 207mm | ||
Height 47.5mm | ||
Weight 340g | ||
Safety Category Level CAT III, CAT IV | ||
Battery Type AA Alkaline | ||
Safety Category Voltage 1000V | ||
Vrijgesteld
- Land van herkomst:
- US
Fluke Multimeter, 1000V Maximum DC Voltage, True RMS Functionality - FLK-3000 FC
Features & Benefits
• True RMS measurement for accurate non‑sinusoidal waveforms
• 400 mA maximum current range for precision current checks
• Frequency measurement to 99.99 kHz for signal verification
• Resistance down to 50 mΩ for low‑ohm integrity testing
• AA battery operation with 250 h minimum battery life for prolonged field use
**Applications**
• Ideal for preventative maintenance log collection and trend analysis
• Used for motor drive frequency and signal validation in automation systems
• Can be used for HVAC temperature checks via K‑type probes
• Used with remote clamp modules for non‑intrusive current monitoring
How is logged data retrieved for analysis on a PC?
What wireless range can be expected through typical site obstacles?
How does the instrument handle non‑sine AC voltages for accuracy?
What logging capacity and granularity are available for extended monitoring?
Which environmental conditions affect measurement performance?
Note
Supplied with
Gerelateerde Links
- Fluke 3000 FC 3000 FC Handheld Digital Multimeter True RMS, 400 mA ac, 400 mA dc, 1 kV ac - UKAS Calibrated
- Fluke 3000 FC 3000 FC Handheld Digital Multimeter True RMS, 400 mA ac, 400 mA dc, 1 kV ac - RSCAL Calibrated
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS, 400 mA dc, 1 kV ac
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS, 400 mA dc, 1 kV ac - UKAS Calibrated
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS, 400 mA dc, 1 kV ac - RSCAL Calibrated
- Fluke V3001 FC 3000 FC Handheld Digital Multimeter, 400 mA dc, 1 kV ac
- Fluke V3001 FC 3000 FC Handheld Digital Multimeter, 400 mA dc, 1 kV ac - UKAS Calibrated
- Fluke V3001 FC 3000 FC Handheld Digital Multimeter, 400 mA dc, 1 kV ac - RSCAL Calibrated
