Fluke 3000 FC 3000 FC Handheld Digital Multimeter True RMS, 400 mA ac, 400 mA dc, 1 kV ac
- RS-stocknr.:
- 811-1316
- Artikelnummer Distrelec:
- 110-83-815
- Fabrikantnummer:
- FLK-3000 FC
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 454,00
(excl. BTW)
€ 549,34
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 80,00
- Plus verzending 4 stuk(s) vanaf 30 maart 2026
- Plus verzending 8 stuk(s) vanaf 30 maart 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 454,00 |
*prijsindicatie
- RS-stocknr.:
- 811-1316
- Artikelnummer Distrelec:
- 110-83-815
- Fabrikantnummer:
- FLK-3000 FC
- Fabrikant:
- Fluke
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Product Type | Multimeter | |
| Multimeter Type | Handheld | |
| Resistance Resolution | 100mΩ | |
| Display Type | Digital | |
| Model Number | 3000 FC | |
| Functions Measured | AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature | |
| Maximum AC Voltage Measurement | 1kV ac | |
| Maximum DC Voltage Measurement | 1kV dc | |
| Maximum AC Current Measurement | 400mA ac | |
| Maximum Resistance Measurement | 50mΩ | |
| Maximum DC Current Measurement | 400mA dc | |
| True RMS | Yes | |
| AC Current Accuracy | ±1.5 % | |
| DC Current Accuracy | ±0.5 % | |
| AC Voltage Accuracy | ±1 % rdg | |
| DC Voltage Accuracy | ±0.09 % | |
| DC Current Resolution | 0.01mA dc | |
| DC Voltage Resolution | 0.1 mV dc | |
| AC Voltage Resolution | 0.1mV ac | |
| AC Current Resolution | 0.01mA ac | |
| Maximum Frequency | 99.99kHz | |
| Resistance Measurement Accuracy | ±0.5 % rdg | |
| Minimum Operating Temperature | -10°C | |
| Battery Life | 250h | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | No | |
| Width | 93mm | |
| Weight | 487.5g | |
| Length | 207mm | |
| Height | 47.5mm | |
| Series | 3000 FC | |
| Safety Category Level | CAT III, CAT IV | |
| Safety Category Voltage | 1000V | |
| Battery Type | AA | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Product Type Multimeter | ||
Multimeter Type Handheld | ||
Resistance Resolution 100mΩ | ||
Display Type Digital | ||
Model Number 3000 FC | ||
Functions Measured AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature | ||
Maximum AC Voltage Measurement 1kV ac | ||
Maximum DC Voltage Measurement 1kV dc | ||
Maximum AC Current Measurement 400mA ac | ||
Maximum Resistance Measurement 50mΩ | ||
Maximum DC Current Measurement 400mA dc | ||
True RMS Yes | ||
AC Current Accuracy ±1.5 % | ||
DC Current Accuracy ±0.5 % | ||
AC Voltage Accuracy ±1 % rdg | ||
DC Voltage Accuracy ±0.09 % | ||
DC Current Resolution 0.01mA dc | ||
DC Voltage Resolution 0.1 mV dc | ||
AC Voltage Resolution 0.1mV ac | ||
AC Current Resolution 0.01mA ac | ||
Maximum Frequency 99.99kHz | ||
Resistance Measurement Accuracy ±0.5 % rdg | ||
Minimum Operating Temperature -10°C | ||
Battery Life 250h | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals No | ||
Width 93mm | ||
Weight 487.5g | ||
Length 207mm | ||
Height 47.5mm | ||
Series 3000 FC | ||
Safety Category Level CAT III, CAT IV | ||
Safety Category Voltage 1000V | ||
Battery Type AA | ||
Vrijgesteld
- Land van herkomst:
- US
Fluke Multimeter, 1000V Maximum DC Voltage, True RMS Functionality - FLK-3000 FC
Features & Benefits
• True RMS measurement for accurate non‑sinusoidal waveforms
• 400 mA maximum current range for precision current checks
• Frequency measurement to 99.99 kHz for signal verification
• Resistance down to 50 mΩ for low‑ohm integrity testing
• AA battery operation with 250 h minimum battery life for prolonged field use
Applications
• Ideal for preventative maintenance log collection and trend analysis
• Used for motor drive frequency and signal validation in automation systems
• Can be used for HVAC temperature checks via K‑type probes
• Used with remote clamp modules for non‑intrusive current monitoring
How is logged data retrieved for analysis on a PC?
What wireless range can be expected through typical site obstacles?
How does the instrument handle non‑sine AC voltages for accuracy?
What logging capacity and granularity are available for extended monitoring?
Which environmental conditions affect measurement performance?
Note
Supplied with
Gerelateerde Links
- Fluke 3000 FC 3000 FC Handheld Digital Multimeter True RMS, 400 mA Max, 400 mA Max, 1000 V ac Max
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS, 400 mA Max, 1000 V Max
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS, 400 mA Max, 1000 V ac Max
- Fluke V3001 FC 3000 FC Handheld Digital Multimeter, 400 mA Max, 1000 V Max
- Fluke V3001 FC 3000 FC Handheld Digital Multimeter, 400 mA Max, 1000 V ac Max
- Facom 714APF Handheld Multimeter True RMS, 400 mA Max, 400 mA Max, 600 V ac Max
- RS PRO S2 Handheld Digital Multimeter True RMS, 400 mA Max, 400 mA Max, 1000 V Max
- RS PRO S2 Handheld Digital Multimeter True RMS, 400 mA Max, 400 mA Max, 1000 V ac Max