Eaton XDP DOL Starter, DOL, 400V ac, 11 kW, 3 Phase, IP65
- RS-stocknr.:
- 528-7432
- Fabrikantnummer:
- 118519 XDP11/I(400V50HZ,440V60HZ)
- Fabrikant:
- Eaton
Afbeelding representeert productcategorie
Subtotaal (1 eenheid)*
€ 346,31
(excl. BTW)
€ 419,04
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Voorradig bij de fabrikant
- Klaar voor verzending vanaf 26 juni 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 346,31 |
*prijsindicatie
- RS-stocknr.:
- 528-7432
- Fabrikantnummer:
- 118519 XDP11/I(400V50HZ,440V60HZ)
- Fabrikant:
- Eaton
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Eaton | |
| Product Type | DOL Starter | |
| Power Rating | 11kW | |
| Sub Type | DOL | |
| Number of Phases | 3 | |
| IP Rating | IP65 | |
| Mount Type | Surface | |
| Number of Poles | 3 | |
| Overall Length | 240mm | |
| Maximum Voltage | 400V ac | |
| Hazardous Area Certification | NO | |
| Overall Width | 160mm | |
| Standards/Approvals | No | |
| Overall Depth | 160mm | |
| Series | XDP | |
| Alles selecteren | ||
|---|---|---|
Merk Eaton | ||
Product Type DOL Starter | ||
Power Rating 11kW | ||
Sub Type DOL | ||
Number of Phases 3 | ||
IP Rating IP65 | ||
Mount Type Surface | ||
Number of Poles 3 | ||
Overall Length 240mm | ||
Maximum Voltage 400V ac | ||
Hazardous Area Certification NO | ||
Overall Width 160mm | ||
Standards/Approvals No | ||
Overall Depth 160mm | ||
Series XDP | ||
Vrijgesteld
- Land van herkomst:
- GB
EATON XDP DOL Starter Series with Isolator
Providing reliability and long operating life, these 'direct-on-line' starters are totally insulated with IP65 protection. Capable of high numbers of operations, these starters are constructed from standard components meaning they are very easy to maintain. Fitted with AC-3 rated triple pole contactor, AC-3 rated triple pole switch disconnector and on and off pushbuttons, these devices also allow for 3 padlocks for additional safety.
All starters in this range are wired to accept EATON overload relays for overload protection, also available from RS components to be purchased separately.
4 & 5.5kW models = H200 x W120 x D160mm, 7.5 & 11kW models = H240 x W160 x D160mm
Features and Benefits:
• Fitted with metric knockouts
• Easy maintenance
• Complies with IEE regulations
• 16th edition on isolation and switching
• Glass fibre reinforced polycarbonate casing
Applications:
Used for starting 3 phase induction motors, direct on line starters are regularly used in industrial applications such as conveyor belts, compressors and small water pumps.
What is the difference between dol and star delta starters?
Both devices are used to start induction motors however, where partial voltage is applied to each winding of a star delta starter, a DOL has 100% voltage applied. This also applies to the current, a star delta uses one-third of the starting current that a DOL does. Direct on line starters are the most common and simplest starting method, within a motor start-up they also provides the lowest temperature rise. Star delta starters allow for starting the motor at a lower voltage, making them suitable for high inertias.
Note
FLC figures quoted are maximum, other overload ratings can be used dependant on FLC rating.
Standards
IEC/EN 60529, DIN 43660, EN 50262
Gerelateerde Links
- Eaton XDP DOL Starter, DOL, 400V ac, 11 kW, 3 Phase, IP55
- Eaton XDP DOL Starter, DOL, 400V ac, 4 kW, 3 Phase, IP65
- Eaton XDP DOL Starter, DOL, 400V ac, 5.5 kW, 3 Phase, IP65
- Eaton XDP DOL Starter, DOL, 400V ac, 7.5 kW, 3 Phase, IP65
- Eaton XDP DOL Starter, DOL, 400V, 4 kW, 3 Phase, IP55
- Eaton XDP DOL Starter, DOL, 400V ac, 5.5 kW, 3 Phase, IP55
- Eaton XDP DOL Starter, DOL, 400V ac, 7.5 kW, 3 Phase, IP55
- Eaton XDP DOL Starter, DOL, 230V ac, 11 kW, 3 Phase, IP55
