Finder Voltage Monitoring Relay, 3 Phase, SPDT, 300 → 480V ac

Subtotaal (1 eenheid)*

€ 115,13

(excl. BTW)

€ 139,31

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 8 stuk(s) klaar voor verzending
  • 26 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 115,13

*prijsindicatie

RS-stocknr.:
789-2746
Artikelnummer Distrelec:
300-71-064
Fabrikantnummer:
70.41.8.400.2030
Fabrikant:
Finder
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Finder

Monitoring Application

Voltage

Electrical Phase

3

Voltage Sensing Range

300 → 480V ac

Contact Configuration

SPDT

Voltage Sensitivity

Overvoltage, Undervoltage

Phase Sensitivity

Phase Asymmetry, Phase Loss, Phase Sequence

Time Delay

0.5 → 60s

Frequency Sensing Range

50 → 60Hz

Series

70

Minimum Operating Temperature

-20°C

Current Range

6A

Dimensions

60.8 x 35 x 88.8mm

Maximum Operating Temperature

+60°C

Height

60.8mm

Length

88.8mm

Width

35mm

Maximum Voltage Sensed

480V ac

Operating Temperature Range

+60°C

Land van herkomst:
IT

Finder Series 70 Monitoring Relay, 3 Electrical Phase, 300 to 480V AC Voltage Sensing Range - 70.41.8.400.2030


This monitoring relay is designed for comprehensive voltage monitoring applications, specifically tailored for three-phase systems. With a voltage sensing range of 300 to 480V AC, it offers reliable functionality in diverse environments. The compact dimensions of 60.8 x 35 x 88.8mm ensure easy installation in various control panels.

Features & Benefits


• Monitors overvoltage, undervoltage, and phase loss accurately
• Adjustable time delay from 0.5 to 60 seconds enhances flexibility
• Positive safety logic opens output contact on error detection
• User-friendly front panel for easy settings adjustment
• Visual indication through coloured LEDs signals operational status
• Designed to operate within -20°C to +60°C temperature range

Applications


• Ideal for monitoring voltage in control panels for pumps
• Utilised in wood-processing machinery and air conditioning systems
• Applicable in hoists and cranes for enhanced safety
• Perfect for escalators, ensuring consistent and safe operation

What happens if the voltage exceeds the rated threshold?


In cases of overvoltage, the relay will open its output contact, ensuring safety and preventing potential damage to connected equipment.

How do I adjust the time delay for the relay?


The time delay can be effortlessly adjusted using the front face selector, allowing settings between 0.5 seconds and 60 seconds according to operational needs.

Is there a memory function for voltage faults?


The relay can be configured to include a fault memory option, which retains the last detected fault until manually reset, providing essential information for troubleshooting.