ABB Phase Monitoring Relay, 1, 3 Phase, DPDT, DIN Rail
- RS-stocknr.:
- 442-9269
- Fabrikantnummer:
- 1SVR450335R0100
- Fabrikant:
- ABB
Afbeelding representeert productcategorie
Niet beschikbaar
RS heeft dit product niet meer op voorraad.
Alternatief
Dit product is momenteel niet beschikbaar. Hierbij onze aanbeveling voor een alternatief product.
la pièce
305,63 €
(excl. BTW)
369,81 €
(incl. BTW)
- RS-stocknr.:
- 442-9269
- Fabrikantnummer:
- 1SVR450335R0100
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Monitoring Application | Phase | |
| Electrical Phase | 1, 3 | |
| Contact Configuration | DPDT | |
| Mounting Type | DIN Rail | |
| Minimum Current Sensed | 2A | |
| Maximum Current Sensed | 20A | |
| Current Sensitivity | Overcurrent, Undercurrent | |
| Phase Sensitivity | Phase Shift | |
| Time Delay | 0.2 → 2s | |
| Series | CM-LWN | |
| Height | 78mm | |
| Length | 100mm | |
| Current Range | 2 → 20A | |
| Operating Temperature Range | +65°C | |
| Minimum Operating Temperature | -25°C | |
| Terminal Type | Screw | |
| Maximum Operating Temperature | +65°C | |
| Dimensions | 100 x 45 x 78mm | |
| Width | 45mm | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Monitoring Application Phase | ||
Electrical Phase 1, 3 | ||
Contact Configuration DPDT | ||
Mounting Type DIN Rail | ||
Minimum Current Sensed 2A | ||
Maximum Current Sensed 20A | ||
Current Sensitivity Overcurrent, Undercurrent | ||
Phase Sensitivity Phase Shift | ||
Time Delay 0.2 → 2s | ||
Series CM-LWN | ||
Height 78mm | ||
Length 100mm | ||
Current Range 2 → 20A | ||
Operating Temperature Range +65°C | ||
Minimum Operating Temperature -25°C | ||
Terminal Type Screw | ||
Maximum Operating Temperature +65°C | ||
Dimensions 100 x 45 x 78mm | ||
Width 45mm | ||
N.v.t.
Load monitor LWN mecotron
Mainly used for asynchronous motors (cage rotors) on a single-phase or 3-phase network with significantly changing loads
The internal electrical isolation of the supply and measuring circuits means it can be used in networks that are separated
Monitors the load status of inductive users
Window monitoring cos φ min. and cos φ max. in one device
2 changeovers
Suppression time for the starting time can be adjusted from 0.3 → 30 s
Single-phase or 3-phase monitoring
3 LEDs for function monitoring
The internal electrical isolation of the supply and measuring circuits means it can be used in networks that are separated
Monitors the load status of inductive users
Window monitoring cos φ min. and cos φ max. in one device
2 changeovers
Suppression time for the starting time can be adjusted from 0.3 → 30 s
Single-phase or 3-phase monitoring
3 LEDs for function monitoring
Load monitor
Using the load monitor allows all machines that are driven by electric motors to be monitored securely. This load monitor can be used for early detection of damage to the bearings or gear, blockage or idling of the screw-conveyors or conveyor belts, as well as V-belt failures or filter blockages, in order to prevent more severe damage or machine failures.
The Telehaase load monitor does not require additional sensors or transducers. It can be used without a current transformer from 230 to 6930 W. Even when operating a frequency inverter, monitoring tasks are completed easily. With all load monitors, start-up bridging and a switching delay can be calibrated.
The Telehaase load monitor does not require additional sensors or transducers. It can be used without a current transformer from 230 to 6930 W. Even when operating a frequency inverter, monitoring tasks are completed easily. With all load monitors, start-up bridging and a switching delay can be calibrated.
Gerelateerde Links
- ABB Phase Monitoring Relay, 3 Phase, DPDT, DIN Rail
- ABB Phase Monitoring Relay, 3 Phase, DPDT, 300 → 500V ac, DIN Rail
- ABB Current Monitoring Relay, 1 Phase, DPDT, DIN Rail
- Crouzet Phase Monitoring Relay, 3 Phase, DPDT, DIN Rail
- Pilz Phase Monitoring Relay, 3 Phase, DPDT, DIN Rail
- ABB Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 90 → 170V ac, DIN Rail
- ABB Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 450 → 720V ac, DIN Rail
- ABB Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 300 → 500V ac, DIN Rail