Schneider Electric Insulation Monitoring Relay, SPDT, Clip-On
- RS-stocknr.:
- 272-7465
- Fabrikantnummer:
- IMD-IM20-H
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 3.639,87
(excl. BTW)
€ 4.404,24
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- Plus verzending 1 stuk(s) vanaf 15 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 3.639,87 |
*prijsindicatie
- RS-stocknr.:
- 272-7465
- Fabrikantnummer:
- IMD-IM20-H
- Fabrikant:
- Schneider Electric
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Monitoring Application | Insulation | |
| Contact Configuration | SPDT | |
| Mounting Type | Clip-On | |
| Maximum Current Sensed | 0.2mA | |
| Series | Vigilohm | |
| Dimensions | 110 x 96mm | |
| Current Range | 0 → 0.2mA | |
| Maximum Voltage Sensed | 25V | |
| Terminal Type | Screw | |
| Special Features | IP52 | |
| Standards Met | IEC 61010-1 | |
| Length | 110mm | |
| Maximum Operating Temperature | +55°C | |
| Width | 96mm | |
| Height | 110mm | |
| Minimum Operating Temperature | -25°C | |
| Operating Temperature Range | -25 → 55°C | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Monitoring Application Insulation | ||
Contact Configuration SPDT | ||
Mounting Type Clip-On | ||
Maximum Current Sensed 0.2mA | ||
Series Vigilohm | ||
Dimensions 110 x 96mm | ||
Current Range 0 → 0.2mA | ||
Maximum Voltage Sensed 25V | ||
Terminal Type Screw | ||
Special Features IP52 | ||
Standards Met IEC 61010-1 | ||
Length 110mm | ||
Maximum Operating Temperature +55°C | ||
Width 96mm | ||
Height 110mm | ||
Minimum Operating Temperature -25°C | ||
Operating Temperature Range -25 → 55°C | ||
- Land van herkomst:
- IN
The Schneider Electric device belongs to the vigil ohm range designed to monitor ungrounded/IT electrical networks, in accordance to installation and products standards. It measures the system insulation resistance by injecting a low frequency AC current between the network and ground.
Auto-test
HMI screen
Protection is IP52 and rear IP20
RS485 communication port and Modbus protocol
HMI screen
Protection is IP52 and rear IP20
RS485 communication port and Modbus protocol
Gerelateerde Links
- Schneider Electric Insulation Monitoring Relay, SPDT
- Schneider Electric Monitoring Relay
- Schneider Electric Insulation Monitoring Relay, Single Phase, SPDT, 110 → 230V ac, Flush Mount
- Schneider Electric Insulation Monitoring Relay, DPDT, Flush Mount
- Siemens Current Monitoring Relay, SPDT, Clip-On
- Schneider Electric Insulation Monitoring Relay, SPDT, 100 → 440V ac/dc, Flush Mount
- Schneider Electric Current Monitoring Relay, DIN Rail
- Siemens Voltage Monitoring Relay, Clip-On