Dold Frequency Monitoring Relay, SPDT, DIN Rail
- RS-stocknr.:
- 181-2792
- Fabrikantnummer:
- MK9143N.38 +/-5Hz UH=AC230V tv=0-20s tan=0-30s
- Fabrikant:
- Dold
Subtotaal (1 eenheid)*
€ 264,40
(excl. BTW)
€ 319,92
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Tijdelijk niet op voorraad
- Verzending vanaf 07 januari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 264,40 |
*prijsindicatie
- RS-stocknr.:
- 181-2792
- Fabrikantnummer:
- MK9143N.38 +/-5Hz UH=AC230V tv=0-20s tan=0-30s
- Fabrikant:
- Dold
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Dold | |
| Monitoring Application | Frequency | |
| Contact Configuration | SPDT | |
| Mounting Type | DIN Rail | |
| Time Delay | 0 → 20 s, 0 → 30s | |
| Frequency Sensing Range | ±5Hz | |
| Series | MK9143N | |
| Frequency Sensitivity | Overfrequency, Underfrequency | |
| Maximum Frequency Sensed | +5Hz | |
| Length | 97mm | |
| Dimensions | 97 x 22.5 x 90mm | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | +60°C | |
| Width | 22.5mm | |
| Minimum Frequency Sensed | -5Hz | |
| Height | 90mm | |
| Operating Temperature Range | +60°C | |
| Terminal Type | Screw | |
| Alles selecteren | ||
|---|---|---|
Merk Dold | ||
Monitoring Application Frequency | ||
Contact Configuration SPDT | ||
Mounting Type DIN Rail | ||
Time Delay 0 → 20 s, 0 → 30s | ||
Frequency Sensing Range ±5Hz | ||
Series MK9143N | ||
Frequency Sensitivity Overfrequency, Underfrequency | ||
Maximum Frequency Sensed +5Hz | ||
Length 97mm | ||
Dimensions 97 x 22.5 x 90mm | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature +60°C | ||
Width 22.5mm | ||
Minimum Frequency Sensed -5Hz | ||
Height 90mm | ||
Operating Temperature Range +60°C | ||
Terminal Type Screw | ||
- Land van herkomst:
- DE
Monitoring of local generator sets and voltage supplies
For precise frequency measuring with fast response time
High disturbance immunity
Separately adjustable trip points and separate outputs for over-
and under frequency (1 or 2 c/o each)
MK 9143N / MH 9143:
Trip points adjustable precisely and reproducible on 10 step rotational switch in the range of ± 0,1 Hz to ± 5 Hz related to 50 or 60 Hz
Nominal frequency 50 or 60 Hz selectable
Fixed hysteresis optimised for trip point
As option one common output for under and over frequency Window-mode (MK 9143N/400 / MH 9143/400)
Variable alarm value in the range of 45 to 65 Hz
Hysteresis adjustable for under- and over frequency separatelyadjustable 0 …20% Common output for under and over frequency Window-mode can be selected
Start up delay 0…30 s selectable
Manual or auto reset selectable
Output relay energized or de-energized on trip selectable for
over frequency
Output relay de-energized on trip for under frequency
Universal frequency measuring input for AC 40 … 550V
Several options for auxiliary supply
LED indicators for auxiliary supply, input frequency, over and
under frequency alarm
For precise frequency measuring with fast response time
High disturbance immunity
Separately adjustable trip points and separate outputs for over-
and under frequency (1 or 2 c/o each)
MK 9143N / MH 9143:
Trip points adjustable precisely and reproducible on 10 step rotational switch in the range of ± 0,1 Hz to ± 5 Hz related to 50 or 60 Hz
Nominal frequency 50 or 60 Hz selectable
Fixed hysteresis optimised for trip point
As option one common output for under and over frequency Window-mode (MK 9143N/400 / MH 9143/400)
Variable alarm value in the range of 45 to 65 Hz
Hysteresis adjustable for under- and over frequency separatelyadjustable 0 …20% Common output for under and over frequency Window-mode can be selected
Start up delay 0…30 s selectable
Manual or auto reset selectable
Output relay energized or de-energized on trip selectable for
over frequency
Output relay de-energized on trip for under frequency
Universal frequency measuring input for AC 40 … 550V
Several options for auxiliary supply
LED indicators for auxiliary supply, input frequency, over and
under frequency alarm
Gerelateerde Links
- Dold Frequency Monitoring Relay, SPDT, DIN Rail
- Dold Monitoring Relay, SPDT, 24 → 240V ac/dc, DIN Rail
- Dold Frequency Monitoring Relay, DPDT, 15 → 280V ac, DIN Rail
- Dold Monitoring Relay
- Dold Current Monitoring Relay with SPDT Contacts, 230 V ac
- Dold Speed Monitoring Relay, DPDT, DIN Rail
- Dold Cycle Monitoring Relay, SPDT, 230V ac, DIN Rail
- Dold Standstill Monitoring Relay, 1, 3 Phase, 3PDT, DIN Rail