Dold Insulation Monitoring Relay, 1, 3 Phase, DPDT, 0 → 500V ac, DIN Rail
- RS-stocknr.:
- 181-2773
- Fabrikantnummer:
- MK5880N.12 DC24V 5-100kOhm
- Fabrikant:
- Dold
Subtotaal (1 eenheid)*
€ 249,29
(excl. BTW)
€ 301,64
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Tijdelijk niet op voorraad
- Verzending 1 stuk(s) vanaf 15 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 249,29 |
*prijsindicatie
- RS-stocknr.:
- 181-2773
- Fabrikantnummer:
- MK5880N.12 DC24V 5-100kOhm
- Fabrikant:
- Dold
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Dold | |
| Monitoring Application | Insulation | |
| Electrical Phase | 1, 3 | |
| Voltage Sensing Range | 0 → 500V ac | |
| Contact Configuration | DPDT | |
| Mounting Type | DIN Rail | |
| Series | MK5880N | |
| Length | 97mm | |
| Minimum Voltage Sensed | 0V ac | |
| Dimensions | 97 x 22.5 x 90mm | |
| Operating Temperature Range | +60°C | |
| Maximum Voltage Sensed | 500V ac | |
| Terminal Type | Screw | |
| Minimum Operating Temperature | -20°C | |
| Height | 90mm | |
| Width | 22.5mm | |
| Maximum Operating Temperature | +60°C | |
| Alles selecteren | ||
|---|---|---|
Merk Dold | ||
Monitoring Application Insulation | ||
Electrical Phase 1, 3 | ||
Voltage Sensing Range 0 → 500V ac | ||
Contact Configuration DPDT | ||
Mounting Type DIN Rail | ||
Series MK5880N | ||
Length 97mm | ||
Minimum Voltage Sensed 0V ac | ||
Dimensions 97 x 22.5 x 90mm | ||
Operating Temperature Range +60°C | ||
Maximum Voltage Sensed 500V ac | ||
Terminal Type Screw | ||
Minimum Operating Temperature -20°C | ||
Height 90mm | ||
Width 22.5mm | ||
Maximum Operating Temperature +60°C | ||
- Land van herkomst:
- DE
For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 1000 Hz
Monitors also disconnected voltage systems
Adjustable tripping value RALof 5 ... 100 kΩ
De-energized on trip
Auxiliary voltage, measuring circuit and output contacts are galvanically separated
Manual and auto reset
With test and reset button
Connections for external test and reset buttons possible
LED indicators for operation and alarm
2 changeover contacts
MK 5880N/200 with additional pre warning
adjustable pre warning value 10 kΩ ... 5 MΩ
1 output relay for alarm and 1 for pre-warning
MH 5880/500: similar to MK 5880N but with galvanic separated analogue output and 11 step LED chain for the actual insulation value
Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
As option with pluggable terminal blocks for easy exchange of devices
with screw terminals
or with cage clamp terminals
Monitors also disconnected voltage systems
Adjustable tripping value RALof 5 ... 100 kΩ
De-energized on trip
Auxiliary voltage, measuring circuit and output contacts are galvanically separated
Manual and auto reset
With test and reset button
Connections for external test and reset buttons possible
LED indicators for operation and alarm
2 changeover contacts
MK 5880N/200 with additional pre warning
adjustable pre warning value 10 kΩ ... 5 MΩ
1 output relay for alarm and 1 for pre-warning
MH 5880/500: similar to MK 5880N but with galvanic separated analogue output and 11 step LED chain for the actual insulation value
Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
As option with pluggable terminal blocks for easy exchange of devices
with screw terminals
or with cage clamp terminals
Gerelateerde Links
- Dold Insulation Monitoring Relay, 1, 3 Phase, DPDT, 0 → 500V ac, DIN Rail
- Dold Insulation Monitoring Relay, 1, 3 Phase, SPDT, 0 → 500V ac, DIN Rail
- Dold Voltage Monitoring Relay, 1, 3 Phase, DPDT, 0 → 500V ac, DIN Rail
- Dold Current Monitoring Relay, DPDT, DIN Rail
- Dold Multifunction Monitoring Relay, DPDT, DIN Rail
- Dold Speed Monitoring Relay, DPDT, DIN Rail
- Dold Temperature Monitoring Relay with DPDT Contacts, 24 V ac/dc
- Dold Frequency Monitoring Relay, DPDT, 15 → 280V ac, DIN Rail
