Dold Residual Current Monitoring Relay, 2 Phase, DPDT, DIN Rail
- RS-stocknr.:
- 181-2768
- Fabrikantnummer:
- RN5883.12/61 AC/DC24-80V 10-3000mA 0-10s
- Fabrikant:
- Dold
Subtotaal (1 eenheid)*
€ 607,40
(excl. BTW)
€ 734,95
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- 1 stuk(s) klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 607,40 |
*prijsindicatie
- RS-stocknr.:
- 181-2768
- Fabrikantnummer:
- RN5883.12/61 AC/DC24-80V 10-3000mA 0-10s
- Fabrikant:
- Dold
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Dold | |
| Monitoring Application | Residual Current | |
| Electrical Phase | 2 | |
| Contact Configuration | DPDT | |
| Mounting Type | DIN Rail | |
| Minimum Current Sensed | 10mA | |
| Maximum Current Sensed | 3000mA | |
| Time Delay | 0 → 10s | |
| Series | RN5883 | |
| Maximum Operating Temperature | +60°C | |
| Width | 52.5mm | |
| Current Range | 10 → 3000mA | |
| Minimum Operating Temperature | -40°C | |
| Terminal Type | Screw | |
| Length | 71mm | |
| Dimensions | 71 x 52.5 x 90mm | |
| Operating Temperature Range | +60°C | |
| Height | 90mm | |
| Alles selecteren | ||
|---|---|---|
Merk Dold | ||
Monitoring Application Residual Current | ||
Electrical Phase 2 | ||
Contact Configuration DPDT | ||
Mounting Type DIN Rail | ||
Minimum Current Sensed 10mA | ||
Maximum Current Sensed 3000mA | ||
Time Delay 0 → 10s | ||
Series RN5883 | ||
Maximum Operating Temperature +60°C | ||
Width 52.5mm | ||
Current Range 10 → 3000mA | ||
Minimum Operating Temperature -40°C | ||
Terminal Type Screw | ||
Length 71mm | ||
Dimensions 71 x 52.5 x 90mm | ||
Operating Temperature Range +60°C | ||
Height 90mm | ||
- Land van herkomst:
- DE
For AC and DC systems Type B
To detect earth faults in grounded voltage systems
4 setting ranges from 10 mA to 3 A
Manual reset, with alarm and pre-warning
With adjustable switching delay
Energized or de-energized on trip
LED indicator for operation, pre-alarm and alarm
With test function
LED-chain indicates fault current
As option with analogue output
Broken wire detection
Width: 52.5 mm
Advantages / Customer benefit
Preventive fire and system protection
Increasing the availability of plants by early fault detection
Universal usage at AC/DC mains
Protection against manipulation by seal able transparent cover
over setting switches
Application
The residual current monitor type B is designed to monitor DC systems
and AC systems up to 250 Hz.
To detect earth faults in grounded voltage systems
4 setting ranges from 10 mA to 3 A
Manual reset, with alarm and pre-warning
With adjustable switching delay
Energized or de-energized on trip
LED indicator for operation, pre-alarm and alarm
With test function
LED-chain indicates fault current
As option with analogue output
Broken wire detection
Width: 52.5 mm
Advantages / Customer benefit
Preventive fire and system protection
Increasing the availability of plants by early fault detection
Universal usage at AC/DC mains
Protection against manipulation by seal able transparent cover
over setting switches
Application
The residual current monitor type B is designed to monitor DC systems
and AC systems up to 250 Hz.
Gerelateerde Links
- Dold Residual Current Monitoring Relay, 2 Phase, DPDT, DIN Rail
- Dold Monitoring Relay, DPDT, 24 → 400V ac/dc, DIN Rail
- Dold Cycle Monitoring Relay, DPDT, 12 → 240V ac/dc, DIN Rail
- Dold Speed Monitoring Relay, DPDT, DIN Rail
- Siemens Residual Current Monitoring Relay, Single Phase, DPDT, DIN Rail
- Dold Voltage Monitoring Relay, DPDT, DIN Rail
- Dold Current Monitoring Relay, DPDT, DIN Rail
- Dold Multifunction Monitoring Relay, DPDT, DIN Rail