Broyce Control Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 243 → 540 V, DIN Rail

Subtotaal (1 eenheid)*

€ 112,89

(excl. BTW)

€ 136,60

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 3 stuk(s) vanaf 08 december 2025
  • Plus verzending 9 stuk(s) vanaf 16 januari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 112,89

*prijsindicatie

RS-stocknr.:
135-6186
Fabrikantnummer:
LPRA/2 400V
Fabrikant:
Broyce Control
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Broyce Control

Monitoring Application

Phase, Voltage

Electrical Phase

3

Contact Configuration

DPDT

Voltage Sensing Range

243 → 540 V

Voltage Sensitivity

Undervoltage

Mounting Type

DIN Rail

Phase Sensitivity

Phase Asymmetry, Phase Failure, Phase Sequence

Time Delay

0.2 → 10s

Series

L

Maximum Operating Temperature

+60°C

Height

89mm

Minimum Operating Temperature

-20°C

Dimensions

66.5 x 17.5 x 89mm

Minimum Voltage Sensed

243 V

Length

66.5mm

Width

17.5mm

Number of Poles

2

Special Features

Microprocessor Based, Detects Incorrect Phase Sequence, Phase Loss And Neutral Loss, Adjustment For Asymmetry Trip Level, Adjustment For Time Delay, Green Led Indication For Supply Status

Terminal Type

Screw

Maximum Voltage Sensed

540V

Operating Temperature Range

+60°C

Land van herkomst:
GB

LPRA/2 Phase Asymmetry, Failure, Sequence, Under Voltage plus Time Delay


Broyce Controls L-Series signal conditioners use a QR barcode marking method allowing direct access to all technical data sheets, ensuring correct information is always at your finger tips!

Features and Benefits


Compact 17.5 mm DIN Rail housing

Microprocessor based

True R.M.S. monitoring measuring phase to phase (three wire) or phase to neutral (4-wire) voltages

Selectable nominal voltages to suit most popular three wire or 4-wire supply voltages

Monitors own supply and detects phase asymmetry/unbalance

Detects incorrect phase sequence, phase loss and neutral loss1

Adjustment for Asymmetry trip level

Adjustment for time delay

DPDT relay output 5A

Green LED indication for supply status

Red LED indication for relay status

Approvals

UL Certification


Broyce Monitor Relays


Relay controllers manufactured using flame retardant material to UL94 VO
Electrical life: ≥150 000 operations
Suitable for use within ambient temperature environments from -20 to +60°C (except stock no. 361-1710 and 361-1681 which are suitable from -20 to +50°C)

Note

Output relay contact rating specified at 250Vac