Crouzet Voltage Monitoring Relay, 3 Phase, DPDT, 96 → 332V ac, DIN Rail
- RS-stocknr.:
- 262-205
- Fabrikantnummer:
- 84873221
- Fabrikant:
- Crouzet
Momenteel niet beschikbaar
Sorry, we weten niet wanneer dit weer voorradig zal zijn.
Alternatief
Dit product is momenteel niet beschikbaar. Hierbij onze aanbeveling voor een alternatief product.
la pièce
196,89 €
(excl. BTW)
238,24 €
(incl. BTW)
- RS-stocknr.:
- 262-205
- Fabrikantnummer:
- 84873221
- Fabrikant:
- Crouzet
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Crouzet | |
| Monitoring Application | Voltage | |
| Electrical Phase | 3 | |
| Voltage Sensing Range | 96 → 332V ac | |
| Contact Configuration | DPDT | |
| Voltage Sensitivity | Overvoltage, Undervoltage | |
| Mounting Type | DIN Rail | |
| Time Delay | 0.3 → 30s | |
| Series | H3USN | |
| Operating Temperature Range | +50°C | |
| Maximum Voltage Sensed | 332V ac | |
| Dimensions | 69 x 35 x 92.6mm | |
| Maximum Operating Temperature | +50°C | |
| Width | 35mm | |
| Minimum Operating Temperature | -20°C | |
| Minimum Voltage Sensed | 96V ac | |
| Height | 92.6mm | |
| Length | 69mm | |
| Alles selecteren | ||
|---|---|---|
Merk Crouzet | ||
Monitoring Application Voltage | ||
Electrical Phase 3 | ||
Voltage Sensing Range 96 → 332V ac | ||
Contact Configuration DPDT | ||
Voltage Sensitivity Overvoltage, Undervoltage | ||
Mounting Type DIN Rail | ||
Time Delay 0.3 → 30s | ||
Series H3USN | ||
Operating Temperature Range +50°C | ||
Maximum Voltage Sensed 332V ac | ||
Dimensions 69 x 35 x 92.6mm | ||
Maximum Operating Temperature +50°C | ||
Width 35mm | ||
Minimum Operating Temperature -20°C | ||
Minimum Voltage Sensed 96V ac | ||
Height 92.6mm | ||
Length 69mm | ||
M3U/H3U series three-phase voltage control relays
H3US and M3US relays control three-phase networks: Overvoltage between phases and undervoltage between phases.
The H3USN relay controls three-phase networks: Overvoltage between phases and neutral, undervoltage between phases and neutral, and the absence of neutral.
Multi-voltage products.
Controls its own voltage supply.
Measurement in true RMS.
LED status display.
The H3USN relay controls three-phase networks: Overvoltage between phases and neutral, undervoltage between phases and neutral, and the absence of neutral.
Multi-voltage products.
Controls its own voltage supply.
Measurement in true RMS.
LED status display.
Gerelateerde Links
- Crouzet Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 194 → 528 V, DIN Rail
- Crouzet Phase Monitoring Relay, 3 Phase, DPDT, DIN Rail
- Crouzet Voltage Monitoring Relay, 3 Phase, DPDT, 194 → 528V ac, DIN Rail
- Crouzet Current Monitoring Relay, 3 Phase, DPDT, DIN Rail
- Crouzet Voltage Monitoring Relay, DPDT, 15 → 600 V, DIN Rail
- Crouzet Voltage Monitoring Relay, DPDT, 0.2 → 60 V, DIN Rail
- Crouzet Voltage Monitoring Relay, 1 Phase, SPDT, DIN Rail
- Crouzet Phase, Voltage Monitoring Relay, 3 Phase, SPDT, 183 → 528V ac, DIN Rail