Eaton xEffect MCB, 2P, 16A Curve C, 230 → 400V AC, 6 kA Breaking Capacity
- RS-stocknr.:
- 769-4564
- Fabrikantnummer:
- 239103 FAZ6-C16/2
- Fabrikant:
- Eaton
Subtotaal (1 eenheid)*
€ 58,47
(excl. BTW)
€ 70,75
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- Plus verzending 2 stuk(s) vanaf 15 december 2025
- Plus verzending 1 stuk(s) vanaf 15 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 58,47 |
*prijsindicatie
- RS-stocknr.:
- 769-4564
- Fabrikantnummer:
- 239103 FAZ6-C16/2
- Fabrikant:
- Eaton
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Eaton | |
| Number of Poles | 2 | |
| Current Rating | 16A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 230 → 400V | |
| Breaking Capacity at Maximum Voltage Rating | 6 kA | |
| Range | xEffect | |
| Circuit Breaker Type | MCB | |
| Width | 17.5mm | |
| Length | 80mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 62mm | |
| Alles selecteren | ||
|---|---|---|
Merk Eaton | ||
Number of Poles 2 | ||
Current Rating 16A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 230 → 400V | ||
Breaking Capacity at Maximum Voltage Rating 6 kA | ||
Range xEffect | ||
Circuit Breaker Type MCB | ||
Width 17.5mm | ||
Length 80mm | ||
Mounting Style DIN Rail Mount | ||
Depth 62mm | ||
Eaton MCB, 16A Current Rating, Type C Tripping Characteristics - 239103 FAZ6-C16/2
This is a compact MCB designed for low voltage circuit protection. With a current rating of 16A and two poles, it offers reliable performance in a variety of electrical installations. The dimensions are 85mm in length and 35.4mm in width, making it suitable for DIN rail mounting in control panels or distribution boards. Its robust tripping characteristics are categorically defined as Type C.
Features & Benefits
• Combines two poles for enhanced circuit protection
• Capable of tripping between 230 to 400V
• Delivers a breaking capacity of 6 kA
• Temperature rise calculations can be handled by panel builders
• Is compliant with RoHS standards for environmental safety
• Features a toggle switch type for easy reset
• Capable of tripping between 230 to 400V
• Delivers a breaking capacity of 6 kA
• Temperature rise calculations can be handled by panel builders
• Is compliant with RoHS standards for environmental safety
• Features a toggle switch type for easy reset
Applications
• Used for electrical installations requiring compact circuit breakers
• Often integrated in electrical distribution panels
• Suitable for protective functions in motor circuits
• Commonly deployed in industrial automation systems
• Often integrated in electrical distribution panels
• Suitable for protective functions in motor circuits
• Commonly deployed in industrial automation systems
What type of mounting is needed for this circuit breaker?
It is designed for DIN rail mounting, allowing easy installation in standard enclosures.
How does it handle short-circuit situations?
The circuit breaker has a short-circuit breaking capacity of 6 kA, ensuring protection against faults.
What are the operational limits in terms of temperature?
This device operates effectively at temperatures ranging from -25°C to a maximum of 75°C.
What is the range of compatible conductor cross-sections?
It accommodates solid-core conductors from 1mm² to 25mm², thus providing flexibility in wiring options.
What is the significance of reactive characteristics defined as Type C?
Type C characteristics are ideal for applications with inductive loads, providing an appropriate response during overcurrent situations.
Note
Eaton formerly known as Moeller
FAZ MCB's
Gerelateerde Links
- Eaton xEffect MCB, 4P, 16A Curve C, 230 → 400V AC, 6 kA Breaking Capacity
- Eaton xEffect MCB, 3P, 16A Curve C, 230 → 400V AC, 6 kA Breaking Capacity
- Eaton xEffect MCB, 1P, 16A Curve C, 230 → 400V AC, 6 kA Breaking Capacity
- Eaton xEffect MCB, 2P, 16A Curve B, 230 → 400V AC, 6 kA Breaking Capacity
- Eaton xEffect MCB, 2P, 16A Curve D, 230 → 400V AC, 6 kA Breaking Capacity
- Eaton xEffect MCB, 16A Curve B, 230 → 400V AC, 6 kA Breaking Capacity
- Eaton xEffect MCB, 2P, 4A Curve C, 230 → 400V AC, 6 kA Breaking Capacity
- Eaton xEffect MCB, 2P, 63A Curve D, 230 → 400V AC, 6 kA Breaking Capacity