ABB S802 Circuit Breaker, 2-Pole, 32A, Type C, 690V ac AC, 250 V dc DC, 50 kA Breaking Capacity

Subtotaal (1 eenheid)*

€ 166,58

(excl. BTW)

€ 201,56

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 7 stuk(s) vanaf 05 november 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 166,58

*prijsindicatie

RS-stocknr.:
287-6380
Artikelnummer Distrelec:
302-43-420
Fabrikantnummer:
2CCS862001R0324
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Number of Poles

2

Product Type

Circuit Breaker

Current Rating

32A

Tripping Characteristics

Type C

Rated AC Voltage

690V ac

Rated DC Voltage

250V dc

Mount Type

DIN Rail

Breaking Capacity

50kA

Series

S802

Terminal Type

Cage Terminal with Captive Screw

IP Rating

IP20

Height

95mm

Width

54mm

Standards/Approvals

IEC/EN 60898-1, IEC/EN 60947-2, UL 1077

Depth

82.5mm

Tripping Mechanism

Anaerobic Adhesive, Electromechanic

Land van herkomst:
CH

ABB S800S Series Circuit Breaker, 32A Current, 50kA Breaking Capacity - 2CCS862001R0324


This circuit breaker is a Compact protective device designed for DIN-rail installation in electrical distribution and control panels. It interrupts overloads and short circuits using a combined thermal and electromechanical trip arrangement. The unit is intended for AC and DC installations offering a resettable I/O actuator and screw-type line connections.

Features and Benefits:


• 32A current rating providing consistent overcurrent protection
• 50kA breaking capacity limiting fault energy during short circuits
• Type C tripping curve protecting moderate inrush equipment
• Rated for 690V ac operation supporting high-voltage AC systems
• 250V dc rating enabling use in DC control circuits

Applications


• Suitable for industrial DIN-rail 32A breaker installations
• Ideal for motor feeder protection with moderate inrush currents
• Used with control panels requiring 250V DC resettable breaker capability
• Can be used for distribution boards needing Type C 50kA MCB 690V performance

What Terminal connection method does it use?


It employs screw terminals to secure conductors and ensure robust electrical contact.

How is it mounted within panel assemblies?


The device clips onto a DIN rail for straightforward installation and removal.

What pole configuration is available for single-line isolation?


It is supplied as a 2-pole unit to interrupt two conductors simultaneously.

What reset and operation Interface is provided?


A dedicated I/O reset actuator allows manual resetting after trip events.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres

De persoonlijke gegevens die u aan ons verstrekt bij het aanmelden voor deze mailinglijst worden verwerkt in overeenstemming met ons privacybeleid.