ABB S200M S202M Circuit Breaker, 2-Pole, 4A, Type K, 440V ac AC, 440 V dc DC, 10 kA Breaking Capacity

Subtotaal (1 eenheid)*

€ 114,83

(excl. BTW)

€ 138,94

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 9 stuk(s) vanaf 05 november 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 114,83

*prijsindicatie

RS-stocknr.:
287-6363
Artikelnummer Distrelec:
302-42-358
Fabrikantnummer:
2CDS272061R0337
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Product Type

Circuit Breaker

Number of Poles

2

Current Rating

4A

Tripping Characteristics

Type K

Rated AC Voltage

440V ac

Rated DC Voltage

440V dc

Breaking Capacity

10kA

Mount Type

Rail

Range

S200M

Series

S202M

Terminal Type

Screw

IP Rating

IP40, IP20

Height

88mm

Depth

69mm

Standards/Approvals

UL 1077, IEC/EN 60947-2, IEC/EN 60898-1, CSA 22.2 No. 235

Width

2mm

Tripping Mechanism

Electromechanic, Anaerobic Adhesive

Land van herkomst:
DE

ABB S200 M UC Series Circuit Breaker, 4A Current, 440V Rated AC Voltage - 2CDS272061R0337


This circuit breaker provides overcurrent protection for two-pole installations in electrical systems. It is designed for DIN-rail mounting and offers manual reclosure via a toggle reset actuator. The device is intended for use where Compact protection and straightforward screw-terminal connections are required.

Features and Benefits:


• 10kA breaking capacity enhances fault interruption capability
• Type K tripping delivers selective response to overloads
• 2-pole configuration enables simultaneous isolation of both conductors
• Screw terminals allow robust conductor termination and maintenance
• IP40 and IP20 ratings offer Basic ingress protection in panel environments

Applications


• Suitable for control panels requiring Compact overcurrent protection
• Ideal for DC bus protection up to 440V d.c. systems
• Used with AC distribution at voltages up to 440V a.c.
• Can be used for machinery secondary circuits needing selective tripping
• Suitable for installations on standard DIN-rail assemblies

What is the rated current and how does it affect circuit selection?


The device is rated at 4A and should be chosen to match expected load currents while providing a protective margin.

Which mounting method is required for installation?


It is designed for DIN-rail mounting to fit standard control panel rails.

How are conductors connected to the device?


Connections are MADE via screw-type terminals for secure wiring termination.

What reset method is provided after a trip event?


A toggle actuator permits manual reset following an interruption.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres

De persoonlijke gegevens die u aan ons verstrekt bij het aanmelden voor deze mailinglijst worden verwerkt in overeenstemming met ons privacybeleid.