ABB S200 S203 Circuit Breaker, 3+N-Pole, 25A, Type C, 440V ac AC, 110 V dc DC, 10 kA Breaking Capacity

Momenteel niet beschikbaar
We weten niet of dit artikel weer voorradig zal zijn, het wordt door de fabrikant stopgezet.

Alternatief

Dit product is momenteel niet beschikbaar. Hierbij onze aanbeveling voor een alternatief product.

RS-stocknr.:
287-6358
Artikelnummer Distrelec:
303-11-491
Fabrikantnummer:
2CDS253103R0254
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Product Type

Circuit Breaker

Number of Poles

3+N

Current Rating

25A

Tripping Characteristics

Type C

Rated AC Voltage

440V ac

Rated DC Voltage

110V dc

Breaking Capacity

10kA

Mount Type

DIN Rail

Range

S200

Series

S203

Terminal Type

Screw

IP Rating

IP40, IP20

Width

35mm

Standards/Approvals

IEC/EN 60898-1, IEC/EN 60947-2, UL1077

Depth

69mm

Height

88mm

Tripping Mechanism

Anaerobic Adhesive, Electromechanic

Land van herkomst:
DE

ABB S200 Series Circuit Breaker, 25A Current, 110V Rated DC Voltage - 2CDS253103R0254


This circuit-breaker is a Compact protective device designed for DIN-rail mounting to interrupt fault currents and protect electrical installations. It combines thermal and electromechanical trip elements to respond to overloads and short circuits, providing protection across both DC and AC circuits in control panels.

Features and Benefits:


• 10 kA breaking capacity limits fault energy and protects downstream equipment
• Type C tripping curve provides enhanced protection for mixed inductive loads
• 25 A rating supports mid-range current distribution requirements
• Screw terminals enable secure conductor connections under vibration
• Toggle reset offers quick manual restoration after trip events

Applications


• Suitable for three-phase systems requiring NEUTRAL protection
• Used with 110 Vdc control circuits in industrial
• Ideal for 440 Vac distribution in switchboards
• Used for Compact DIN-rail installations with limited panel space

How does the trip system handle both overloads and short circuits?


It uses a thermal element for long-duration overloads and an electromechanical element for Rapid fault interruption.

What Terminal connectivity is provided for field wiring?


Termination is by screw-type terminals designed for conventional conductor fastening.

Which ingress protection levels apply to this unit?


The enclosure meets IP40 for the front and IP20 for internal access, defining dust protection and finger-safe barriers.