ABB SMISSLINE TP S402M-C1.6 Miniature Circuit Breaker, 2-Pole, 16A, Type C, 415V ac AC, 10 kA Breaking Capacity

Subtotaal (1 eenheid)*

€ 80,30

(excl. BTW)

€ 97,16

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 4 stuk(s) vanaf 04 november 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 80,30

*prijsindicatie

RS-stocknr.:
246-2570
Fabrikantnummer:
2CCS572001R0164
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Number of Poles

2

Product Type

Miniature Circuit Breaker

Current Rating

16A

Tripping Characteristics

Type C

Rated AC Voltage

415V ac

Breaking Capacity

10kA

Mount Type

DIN Rail

Range

SMISSLINE TP

Series

S402M-C1.6

Terminal Type

0.75 to 25 mm² Rigid

IP Rating

IP20

Width

36mm

Standards/Approvals

IEC/EN 60947-2, IEC/EN 60898-1

Depth

82mm

Height

91mm

Land van herkomst:
CH

ABB S400M Series Miniature Circuit Breaker, 16A Current, 415V ac Rated Voltage - 2CCS572001R0164


This miniature circuit breaker provides overcurrent protection and selective tripping for low-voltage electrical installations. It is designed for two-pole applications where coordinated thermal and electromagnetic interruption is required. The device operates within standard industrial AC systems and is suitable for distribution boards where controlled disconnection and manual reset via a clear I/O actuator are needed.

Features and Benefits:


• Tripping curve Type C limits nuisance trips from moderate inrush currents
• 10kA breaking capacity reduces risk during short-circuit events
• Electromechanical thermal magnetic trip delivers fast and delayed protection
• Screw Terminal ensures secure conductor connection under vibration
• IP20 enclosure rating allows protected indoor panel mounting

Applications


• Suitable for small commercial distribution boards
• Ideal for protecting motor feeders with moderate inrush
• Used for branch circuit protection in residential conversions
• Can be used for lighting circuits in office environments

What pole configuration does it employ?


It uses a two-pole arrangement enabling simultaneous disconnection of both live conductors.

How is the device manually reset after operation?


The unit is reset using an I/O style actuator that clearly indicates switch position.

What type of terminals are provided for conductor attachment?


Termination is via screw-type terminals designed for conventional stranded or solid conductors.

Which standards define its electrical performance?


Performance aligns with IEC/EN 60947-2 and IEC/EN 60898-1.

What is the product's physical footprint for panel planning?


The device measures 36 mm in width, 91 mm in height and 82 mm in depth.