ABB SMISSLINE TP S401M-K10NP Miniature Circuit Breaker, 2-Pole, 10A, Type K, 240V ac AC, 25 kA Breaking Capacity
- RS-stocknr.:
- 246-2541
- Fabrikantnummer:
- 2CCS571103R8427
- Fabrikant:
- ABB
Subtotaal (1 eenheid)*
€ 96,49
(excl. BTW)
€ 116,75
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Op voorraad
- Plus verzending 1 stuk(s) vanaf 05 november 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 96,49 |
*prijsindicatie
- RS-stocknr.:
- 246-2541
- Fabrikantnummer:
- 2CCS571103R8427
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Product Type | Miniature Circuit Breaker | |
| Number of Poles | 2 | |
| Current Rating | 10A | |
| Tripping Characteristics | Type K | |
| Rated AC Voltage | 240V ac | |
| Mount Type | DIN Rail | |
| Breaking Capacity | 25kA | |
| Range | SMISSLINE TP | |
| Series | S401M-K10NP | |
| Terminal Type | Rigid | |
| IP Rating | IP20 | |
| Width | 36mm | |
| Standards/Approvals | IEC/EN 60947-2 | |
| Depth | 82mm | |
| Height | 91mm | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Product Type Miniature Circuit Breaker | ||
Number of Poles 2 | ||
Current Rating 10A | ||
Tripping Characteristics Type K | ||
Rated AC Voltage 240V ac | ||
Mount Type DIN Rail | ||
Breaking Capacity 25kA | ||
Range SMISSLINE TP | ||
Series S401M-K10NP | ||
Terminal Type Rigid | ||
IP Rating IP20 | ||
Width 36mm | ||
Standards/Approvals IEC/EN 60947-2 | ||
Depth 82mm | ||
Height 91mm | ||
- Land van herkomst:
- CH
ABB S400M Series Miniature Circuit Breaker, 10A Current, 2 Poles - 2CCS571103R8427
This miniature circuit breaker provides overcurrent protection for low-voltage AC systems and is designed for installation where Compact two-pole protection is required. It operates on 240V AC supplies and uses a thermal Plus electromechanical trip arrangement to interrupt faults rapidly while allowing normal currents to flow. The unit meets recognised industry switching device standards and is intended for distribution boards and control panels where space efficiency and defined tripping behaviour are needed.
Features and Benefits:
• 25kA breaking capacity offers effective fault interruption
• Type K tripping characteristic protects motor and inductive loads
• Electromechanical thermal tripping ensures coordinated overload response
• Screw terminals enable secure conductor connections
• Reset I/O actuator allows clear on/off status control
• Type K tripping characteristic protects motor and inductive loads
• Electromechanical thermal tripping ensures coordinated overload response
• Screw terminals enable secure conductor connections
• Reset I/O actuator allows clear on/off status control
Applications
• Suitable for protecting small motor circuits and inductive loads
• Used with single-phase distribution to isolate two conductors
• Ideal for Compact consumer units in residential installations
• Can be used for control panel branch-circuit protection
• Used for retrofit upgrades where space is constrained
• Used with single-phase distribution to isolate two conductors
• Ideal for Compact consumer units in residential installations
• Can be used for control panel branch-circuit protection
• Used for retrofit upgrades where space is constrained
What voltage range is this intended to operate on?
It is rated for 240V AC operation suitable for typical single-phase supplies.
How many poles does the device isolate simultaneously?
The device isolates two poles, providing simultaneous interruption of both conductors.
What ingress protection does the enclosure provide?
The enclosure meets IP20, providing protection against solid objects larger than 12 mm but not against liquids.
Which trip behaviour should I expect under overload?
Thermal elements respond to prolonged overloads while the electromechanical mechanism trips on higher instantaneous faults.
Which standard governs its switching and safety characteristics?
It is manufactured to meet IEC/EN 60947-2 requirements.
Gerelateerde Links
- ABB SMISSLINE TP S403M-K10NP Miniature Circuit Breaker, 4-Pole, 10A, Type K, 415V ac AC, 25 kA Breaking Capacity
- ABB SMISSLINE TP S401M-K8 Miniature Circuit Breaker, 1-Pole, 8A, Type K, 240V ac AC, 25 kA Breaking Capacity
- ABB SMISSLINE TP S401M-K13 Miniature Circuit Breaker, 1-Pole, 13A, Type K, 240V ac AC, 10 kA Breaking Capacity
- ABB SMISSLINE TP S401M-K50 Miniature Circuit Breaker, 1-Pole, 50A, Type K, 240V ac AC, 15 kA Breaking Capacity
- ABB SMISSLINE TP S401M-K25 Miniature Circuit Breaker, 1-Pole, 25A, Type K, 240V ac AC, 15 kA Breaking Capacity
- ABB SMISSLINE TP S401M-K0.5 Miniature Circuit Breaker, 1-Pole, 500mA, Type K, 240V ac AC, 10 kA Breaking Capacity
- ABB SMISSLINE TP S401M-K1 Miniature Circuit Breaker, 1-Pole, 1A, Type K, 240V ac AC, 10 kA Breaking Capacity
- ABB SMISSLINE TP S401M-K3 Miniature Circuit Breaker, 1-Pole, 3A, Type K, 240V ac AC, 10 kA Breaking Capacity