Hager NGN NGN Circuit Breaker, 3-Pole, 40 A, Type D, 400 V ac AC, 6 kA Breaking Capacity
- RS-stocknr.:
- 599-790
- Fabrikantnummer:
- NGN340
- Fabrikant:
- Hager
Niet beschikbaar
RS heeft dit product niet meer op voorraad.
Alternatief
Dit product is momenteel niet beschikbaar. Hierbij onze aanbeveling voor een alternatief product.
la pièce
356,06 €
(excl. BTW)
430,83 €
(incl. BTW)
- RS-stocknr.:
- 599-790
- Fabrikantnummer:
- NGN340
- Fabrikant:
- Hager
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Hager | |
| Product Type | Circuit Breaker | |
| Number of Poles | 3 | |
| Current Rating | 40 A | |
| Tripping Characteristics | Type D | |
| Rated AC Voltage | 400 V ac | |
| Breaking Capacity | 6kA | |
| Range | NGN | |
| Series | NGN | |
| Terminal Type | Screw | |
| Width | 52.5 mm | |
| Standards/Approvals | IEC 60947-2, IEC 60898-1 | |
| Depth | 70mm | |
| Height | 83mm | |
| Alles selecteren | ||
|---|---|---|
Merk Hager | ||
Product Type Circuit Breaker | ||
Number of Poles 3 | ||
Current Rating 40 A | ||
Tripping Characteristics Type D | ||
Rated AC Voltage 400 V ac | ||
Breaking Capacity 6kA | ||
Range NGN | ||
Series NGN | ||
Terminal Type Screw | ||
Width 52.5 mm | ||
Standards/Approvals IEC 60947-2, IEC 60898-1 | ||
Depth 70mm | ||
Height 83mm | ||
- Land van herkomst:
- PL
The Hager Circuit breaker with a capacity of 40 amps, is designed to protect electrical circuits against overloads and short circuits. Its breaking capacity of 6 to 10 kA and its D curve allow for rapid disconnection in the event of moderate overcurrents, ideal for tertiary installations. Thanks to its terminals aligned on 3 modules.
REACH compliant
RoHS compliant
Compact and optimizes the space used in the electrical panel
Gerelateerde Links
- Hager Hager NGN Circuit Breaker, 3P, 4A Curve D, 400V AC, 10 kA Breaking Capacity
- Hager Hager NGN Circuit Breaker, 3P, 63A Curve D, 400V AC, 10 kA Breaking Capacity
- Hager Hager NGN Circuit Breaker, 3P, 2A Curve D, 400V AC, 10 kA Breaking Capacity
- Hager Hager NGN Circuit Breaker, 3P, 3A Curve D, 400V AC, 10 kA Breaking Capacity
- Hager Hager NKN Circuit Breaker, 3P, 40A Curve C, 400V AC, 15 kA Breaking Capacity
- Hager NGN MCB, 2P, 40A Curve D, 230 → 400V AC, 6 kA Breaking Capacity
- Hager NGN MCB, 4P, 40A Curve D, 230 → 400V AC, 6 kA Breaking Capacity
- Hager NGN MCB, 3P, 1A Curve D, 400V AC, 10 kA Breaking Capacity