Eaton xPole PXL, S200 MCB, 2P, 16A Curve C, 400V AC, 48V DC, 10 kA Breaking Capacity

Subtotaal (1 eenheid)*

€ 64,40

(excl. BTW)

€ 77,92

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 7 stuk(s) klaar voor verzending
  • 7 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 64,40

*prijsindicatie

RS-stocknr.:
490-179
Fabrikantnummer:
236289 PXL-C16/2
Fabrikant:
Eaton
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Eaton

Number of Poles

2

Current Rating

16A

Tripping Characteristics

Type C

Rated AC Voltage

400V

Rated DC Voltage

48V

Breaking Capacity at Maximum Voltage Rating

10 kA

Range

xPole

Series

PXL, S200

Circuit Breaker Type

MCB

Length

35mm

Width

80mm

Mounting Style

DIN Rail Mount

Depth

60mm

Vrijgesteld

Land van herkomst:
AT

Eaton MCB, 16A Current Rating, Type C Tripping Characteristics - 236289 PXL-C16/2


This Eaton MCB is a high-performance 2-pole circuit breaker designed for efficient electrical protection in residential and commercial applications. Measuring 80mm in length and 35mm in width, it has a rated current of 16A and accommodates up to 400V AC. This device is an integral part of the xPole range, providing reliable circuit protection with its robust breaking capacity.

Features & Benefits


• Complies with IEC/EN 60898-1 for reliable performance
• Ensures high breaking capacity of 10 kA for robust protection
• Type C tripping characteristic for motor protection
• Compatible with standard DIN rail for seamless installation
• Toggle switch for straightforward manual reset and operation
• Effective across a wide temperature range, -25°C to 55°C

Applications


• Used with electrical systems in residential installations
• Applicable for commercial electrical distribution panels
• Ideal for automation and control systems integration
• Suitable for protecting electrical circuits against overloads
• Designed for use in environments requiring compact circuit protection

What is the importance of the Type C tripping characteristic?


Type C tripping characteristics are essential for circuits with moderate overloads, especially in industrial applications where inductive loads are common, preventing nuisance tripping.

How does temperature affect the performance of this circuit breaker?


With an operational temperature range of -25°C to 55°C, significant temperature increases can reduce its current-carrying capacity, an aspect crucial for ensuring consistent performance in warmer environments.

What is the significance of the 10 kA breaking capacity?


A breaking capacity of 10 kA indicates the maximum fault current the device can interrupt without failure, ensuring safety in more demanding electrical installations.

Note

Eaton formerly known as Moeller

Standards

IEC / EN 60898

Gerelateerde Links