Eaton xPole PXL, S200 MCB, 3P, 16A Curve B, 400V AC, 48V DC, 10 kA Breaking Capacity
- RS-stocknr.:
- 489-905
- Fabrikantnummer:
- 236388 PXL-B16/3
- Fabrikant:
- Eaton
Subtotaal (1 eenheid)*
€ 63,75
(excl. BTW)
€ 77,14
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- 15 stuk(s) klaar voor verzending
- 17 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 63,75 |
*prijsindicatie
- RS-stocknr.:
- 489-905
- Fabrikantnummer:
- 236388 PXL-B16/3
- Fabrikant:
- Eaton
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Eaton | |
| Number of Poles | 3 | |
| Current Rating | 16A | |
| Tripping Characteristics | Type B | |
| Rated AC Voltage | 400V | |
| Rated DC Voltage | 48V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xPole | |
| Series | PXL, S200 | |
| Circuit Breaker Type | MCB | |
| Length | 52.5mm | |
| Width | 80mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 60mm | |
| Alles selecteren | ||
|---|---|---|
Merk Eaton | ||
Number of Poles 3 | ||
Current Rating 16A | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 400V | ||
Rated DC Voltage 48V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xPole | ||
Series PXL, S200 | ||
Circuit Breaker Type MCB | ||
Length 52.5mm | ||
Width 80mm | ||
Mounting Style DIN Rail Mount | ||
Depth 60mm | ||
Vrijgesteld
- Land van herkomst:
- AT
PXL series, B characteristic, 3-pole
Circuit breaker with high selectivity as a pre-fuse with low passband energy
Bus bar compatible
With double terminal, lift / jaw top and bottom
Free selection of rail arrangement top and bottom
Finger-proof / back-of-hand-proof
Quick-fit action with 3 locking positions for top-hat rail IEC / EN 60715
Bus bar compatible
With double terminal, lift / jaw top and bottom
Free selection of rail arrangement top and bottom
Finger-proof / back-of-hand-proof
Quick-fit action with 3 locking positions for top-hat rail IEC / EN 60715
Standards
IEC / EN 60898
Eaton Miniature Circuit Breaker, 16A Current Rating, 10kA Breaking Capacity - PXL S200 Series - 236388 PXL-B16/3
Trip an electrical circuit when dangerous overcurrent conditions occur with this miniature circuit breaker (MCB) from Eaton. The type-B device is suitable to use in residential or light commercial applications where switching surges are small. For greater safety, the MCB is insulated and protected against abnormal heat and fire. Resistance to corrosion makes the unit compatible with humid operating environments. A thermally stable enclosure adds to the reliability of the device, as it isn't negatively affected by the presence of heat. MCBs like this are commonly used to protect resistive or small inductive loads.
Features & Benefits
• Offers maximum packing efficiency on a circuit board with compact dimensions of 80 (L) x 52.5 (W) x 75mm (H)
• IP20 (ingress protection) rated enclosure that's protected against touch and objects larger than 12mm
• Wide operating temperature range of -25°C to +75°C for use in demanding environments
• IP20 (ingress protection) rated enclosure that's protected against touch and objects larger than 12mm
• Wide operating temperature range of -25°C to +75°C for use in demanding environments
Is this MCB compatible with AC or DC voltage?
This miniature circuit breaker is compatible with AC voltage and has a maximum capacity of 400V.
What's a type-B MCB?
A type-B MCB, like this one, will trip instantly when it experiences a rate of three to five times its rated current.
Standards
IEC / EN 60898
Gerelateerde Links
- Eaton xPole PXL, S200 MCB, 1P, 16A Curve B, 400V AC, 48V DC, 10 kA Breaking Capacity
- Eaton xPole PXL, S200 MCB, 2P, 16A Curve B, 400V AC, 48V DC, 10 kA Breaking Capacity
- Eaton xPole PXL, S200 MCB, 1P, 16A Curve C, 400V AC, 48V DC, 10 kA Breaking Capacity
- Eaton xPole PXL, S200 MCB, 2P, 16A Curve C, 400V AC, 48V DC, 10 kA Breaking Capacity
- Eaton xPole PXL, S200 MCB, 3P, 16A Curve C, 400V AC, 48V DC, 10 kA Breaking Capacity
- Eaton xPole PXL, S200 MCB, 3P, 16A Curve D, 400V AC, 48V DC, 10 kA Breaking Capacity
- Eaton xPole PXL, S200 MCB, 1P, 16A Curve D, 400V AC, 48V DC, 10 kA Breaking Capacity
- Eaton xPole - PXL PXL MCB, 4P, 16A Curve B, 400V AC, 10 kA Breaking Capacity