Eaton xPole PXL, S200 MCB, 1P, 10A Curve B, 400V AC, 48V DC, 10 kA Breaking Capacity

Subtotaal (1 eenheid)*

€ 12,69

(excl. BTW)

€ 15,35

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Informatie over voorraden is momenteel niet toegankelijk
Aantal stuks
Per stuk
1 +€ 12,69

*prijsindicatie

RS-stocknr.:
486-776
Fabrikantnummer:
236029 PXL-B10/1
Fabrikant:
Eaton
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Eaton

Number of Poles

1

Current Rating

10A

Tripping Characteristics

Type B

Rated AC Voltage

400V

Rated DC Voltage

48V

Breaking Capacity at Maximum Voltage Rating

10 kA

Range

xPole

Series

PXL, S200

Circuit Breaker Type

MCB

Length

17.5mm

Width

80mm

Mounting Style

DIN Rail Mount

Depth

60mm

Vrijgesteld

Land van herkomst:
AT

Eaton MCB, 10A Current Rating, Type B Tripping Characteristics - 236029 PXL-B10/1


This device is a miniature circuit breaker (MCB) in the xPole series by Eaton, specifically designed for applications in residential and commercial settings. With a compact width of 17.5mm and a length of 80mm, it features a single pole and a current rating of 10A. The product supports both AC and DC voltage, functioning effectively at 400V AC and 48V DC.

Features & Benefits


• Type B MCB provides reliable tripping characteristics for protection
• Rated breaking capacity of 10 kA ensures robust fault handling
• Suitable for DIN rail mounting, facilitating easy installation
• Connectable conductor cross section ranges from 1mm² to 25mm²
• Operates within a temperature range of -25 °C to 55 °C
• RoHS compliant for environmentally responsible usage

Applications


• Utilised in switchgear for residential electrical systems
• Ideal for commercial requiring reliable circuit protection
• Employed in automation systems needing adherence to electrical standards
• Suitable for installations involving mixed AC and DC loads

What is the maximum ambient temperature for operation?


The maximum ambient operating temperature is 55 °C, with a minimal impact on current capacity beyond this threshold.

How does the breaking capacity impact circuit safety?


With a breaking capacity of 10 kA, it effectively handles short circuits, ensuring that potential faults do not lead to excessive current flow that could damage the electrical system.

What specifications should be considered for installation?


The device should be connected to suitable conductor sizes, ensuring they remain within the 1mm² to 25mm² range, to optimise performance and safety.

Can this product be used in different voltage systems?


Yes, it operates proficiently with both AC (up to 400V) and DC (up to 48V) voltage systems, offering versatility in a variety of applications.

Standards

IEC / EN 60898