Eaton xEffect FAZ MCB, 2P, 500mA, Type Z, 400V AC, 96V DC, 10 kA Breaking Capacity
- RS-stocknr.:
- 259-191
- Fabrikantnummer:
- 278816 FAZ-Z0,5/2
- Fabrikant:
- Eaton
Subtotaal (1 eenheid)*
€ 110,09
(excl. BTW)
€ 133,21
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Tijdelijk niet op voorraad
- Verzending vanaf 02 februari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 110,09 |
*prijsindicatie
- RS-stocknr.:
- 259-191
- Fabrikantnummer:
- 278816 FAZ-Z0,5/2
- Fabrikant:
- Eaton
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Eaton | |
| Number of Poles | 2 | |
| Current Rating | 500mA | |
| Tripping Characteristics | Type Z | |
| Rated AC Voltage | 400V | |
| Rated DC Voltage | 96V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xEffect | |
| Series | FAZ | |
| Alles selecteren | ||
|---|---|---|
Merk Eaton | ||
Number of Poles 2 | ||
Current Rating 500mA | ||
Tripping Characteristics Type Z | ||
Rated AC Voltage 400V | ||
Rated DC Voltage 96V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xEffect | ||
Series FAZ | ||
Vrijgesteld
- Land van herkomst:
- RO
The Eaton miniature circuit breaker (MCB) from The Eaton Moeller series xEffect is a cornerstone for modern electrical systems, ensuring safety and reliability. Designed for efficiency, this 2 pole MCB delivers a maximum operational current of 0.5 A, making it ideal for a range of applications from branch circuits to industrial switchgear. The compact dimensions of 80 mm in length, 75.5 mm in height, and 36 mm in width facilitate ease of installation in tight spaces, while the IP20 protection guarantees safety against accidental contact. With a tripping characteristic of Z, this circuit breaker provides a tailored performance to prevent overloads or short circuits, safeguarding your electrical installations. Meeting compliance standards such as UL, CSA, and RoHS, it embodies a commitment to quality and safety, making it an essential choice for engineers and technicians alike. Experience peace of mind with intelligent design that protects both the equipment and the end user.
Compact design for space efficient installation in panels
Tripping characteristic optimised for sensitive applications
Robust construction enhances durability in demanding environments
Environmental compliance ensures minimal impact on nature
Versatile usage caters to both industrial and advanced commercial applications
Twin purpose terminals provide flexible connectivity options
Advanced heat dissipation capabilities maintain performance
Clear documentation supports effective implementation and maintenance
Designed for easy integration with existing electrical systems
Tripping characteristic optimised for sensitive applications
Robust construction enhances durability in demanding environments
Environmental compliance ensures minimal impact on nature
Versatile usage caters to both industrial and advanced commercial applications
Twin purpose terminals provide flexible connectivity options
Advanced heat dissipation capabilities maintain performance
Clear documentation supports effective implementation and maintenance
Designed for easy integration with existing electrical systems
Gerelateerde Links
- Eaton xEffect FAZ MCB, 3P, 500mA, Type Z, 400V AC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB, 4P, 500mA, Type Z, 400V AC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB, 2P, 500mA Curve K, 400V AC, 96V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB, 2P, 63A, Type Z, 400V AC, 96V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB, 2P, 50A, Type Z, 400V AC, 96V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB, 2P, 16A, Type Z, 400V AC, 96V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB, 2P, 32A, Type Z, 400V AC, 96V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB, 2P, 40A, Type Z, 400V AC, 96V DC, 10 kA Breaking Capacity