Eaton xPole - PXL PXL MCB, 3P, 13A Curve D, 400V AC, 10 kA Breaking Capacity
- RS-stocknr.:
- 256-167
- Fabrikantnummer:
- 236548 PXL-D13/3N
- Fabrikant:
- Eaton
Subtotaal (1 eenheid)*
€ 154,53
(excl. BTW)
€ 186,98
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Tijdelijk niet op voorraad
- Verzending vanaf 09 februari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 154,53 |
*prijsindicatie
- RS-stocknr.:
- 256-167
- Fabrikantnummer:
- 236548 PXL-D13/3N
- Fabrikant:
- Eaton
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Eaton | |
| Number of Poles | 3 | |
| Current Rating | 13A | |
| Tripping Characteristics | Type D | |
| Rated AC Voltage | 400V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xPole - PXL | |
| Series | PXL | |
| Alles selecteren | ||
|---|---|---|
Merk Eaton | ||
Number of Poles 3 | ||
Current Rating 13A | ||
Tripping Characteristics Type D | ||
Rated AC Voltage 400V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xPole - PXL | ||
Series PXL | ||
- Land van herkomst:
- RO
The Eaton Moeller series xPole - PXL MCB is designed to provide superior protection for residential and commercial switchgear applications. With its robust construction and advanced engineering, it supports critical electrical systems, ensuring safety and reliability. This circuit breaker features a tripping characteristic of D, which is ideal for applications requiring high inrush current handling. Enhanced with an impressive rated current of 13 A and a rated short-circuit breaking capacity of 10 kA, it complies with the latest standards, making it a dependable choice for any installation. The xPole series stands out with its innovative design, facilitating ease of use and installation, alongside superior shielding against electrical faults. Built to withstand temperature variations, it operates seamlessly in ambient temperatures ranging from -25 °C to a maximum of 55 °C.
Three-pole plus neutral design for enhanced versatility
IP20 degree of protection, ensuring adequate safety
Temperature rise calculations are simplified through expert design
Electric shock protection requirements are met, enhancing user safety
Concurrently switches the neutral for comprehensive circuit management
Power-loss ratings are optimised to support efficient electrical operation
Compliant with RoHS standards, prioritising environmental safety
User-friendly installation instructions are included for efficient setup
Robust construction provides resistance to electromagnetic interference
Heat dissipation data available for informed panel building decisions
IP20 degree of protection, ensuring adequate safety
Temperature rise calculations are simplified through expert design
Electric shock protection requirements are met, enhancing user safety
Concurrently switches the neutral for comprehensive circuit management
Power-loss ratings are optimised to support efficient electrical operation
Compliant with RoHS standards, prioritising environmental safety
User-friendly installation instructions are included for efficient setup
Robust construction provides resistance to electromagnetic interference
Heat dissipation data available for informed panel building decisions
Gerelateerde Links
- Eaton xPole - PXL PXL MCB, 2P, 13A Curve D, 400V AC, 10 kA Breaking Capacity
- Eaton xPole - PXL PXL MCB, 4P, 13A Curve D, 400V AC, 10 kA Breaking Capacity
- Eaton xPole - PXL PXL MCB, 3P, 13A Curve C, 400V AC, 10 kA Breaking Capacity
- Eaton xPole - PXL PXL MCB, 3P, 13A Curve B, 400V AC, 10 kA Breaking Capacity
- Eaton xPole PXL, S200 MCB, 3P, 13A Curve D, 400V AC, 48V DC, 10 kA Breaking Capacity
- Eaton xPole PXL, S200 MCB, 1P, 13A Curve D, 400V AC, 48V DC, 10 kA Breaking Capacity
- Eaton xPole - PXL PXL MCB, 1P, 13A Curve D, 230V AC, 10 kA Breaking Capacity
- Eaton xPole - PXL PXL MCB, 4P, 13A Curve C, 400V AC, 10 kA Breaking Capacity