ABB System Pro M Compact S200 M UC Miniature Circuit Breaker, 2-Pole, 5A, Type K, 400V ac AC, 440 V dc DC, 10 kA

Subtotaal (1 eenheid)*

€ 194,68

(excl. BTW)

€ 235,56

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Voorradig bij de fabrikant
  • Klaar voor verzending vanaf 31 december 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 194,68

*prijsindicatie

RS-stocknr.:
204-358
Fabrikantnummer:
2CDS272061R0357
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Number of Poles

2

Product Type

Miniature Circuit Breaker

Current Rating

5A

Tripping Characteristics

Type K

Rated AC Voltage

400V ac

Rated DC Voltage

440V dc

Mount Type

DIN Rail

Breaking Capacity

10kA

Range

System Pro M Compact

Series

S200 M UC

Terminal Type

Screw

IP Rating

IP20, IP40

Standards/Approvals

IEC 60068-2-27, IEC/EN 60664-1, UL1077

Depth

69mm

Height

88mm

Width

2in

Land van herkomst:
DE

ABB S200 M UC Series Miniature Circuit Breaker, 5A Current, 10kA Breaking Capacity - 2CDS272061R0357


This miniature circuit breaker provides overcurrent protection for DC and AC installations. It is designed for DIN-rail mounting and operates with a Type K trip characteristic to manage selective tripping in mixed-load environments. The device accommodates screw terminations and features a toggle reset actuator for manual reclosure.

Features and Benefits:


• 5 A current rating limits continuous load to the specified amperage
• 10 kA breaking capacity isolates high short-circuit currents
• 440 V DC rated voltage supports DC system protection
• 400 V AC rated voltage handles standard AC distribution
• 2-pole configuration enables simultaneous pole disconnection

Applications


• Suitable for control-panel branch-circuit protection
• Ideal for photovoltaic DC string protection schemes
• Used with industrial machinery auxiliary circuits
• Used for selective protection in mixed AC/DC systems

What mounting method is required for installation?


It clips onto a standard DIN rail for quick panel installation.

Which Terminal type is provided for conductor connection?


Screw terminals are used to secure conductors during wiring.

How does the tripping behaviour affect coordination?


The Type K tripping characteristic offers a defined thermal-magnetic response suitable for inductive loads and coordination with upstream devices.

What ingress protection does it offer for component access?


The device carries IP20 protection for general handling and IP40 where indicated for additional front protection.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres

De persoonlijke gegevens die u aan ons verstrekt bij het aanmelden voor deze mailinglijst worden verwerkt in overeenstemming met ons privacybeleid.