ABB S803N Miniature Circuit Breaker, 3-Pole, 20A, Type B, 690V ac AC, 36 kA Breaking Capacity

Subtotaal (1 eenheid)*

€ 267,40

(excl. BTW)

€ 323,55

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Voorradig bij de fabrikant
  • Klaar voor verzending vanaf 07 december 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 267,40

*prijsindicatie

RS-stocknr.:
140-399
Fabrikantnummer:
2CCS893001R0205
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Product Type

Miniature Circuit Breaker

Number of Poles

3

Current Rating

20A

Tripping Characteristics

Type B

Rated AC Voltage

690V ac

Breaking Capacity

36kA

Mount Type

DIN Rail

Series

S803N

Terminal Type

Cage Terminal with Captive Screw

IP Rating

IP20

Depth

82.5mm

Height

95mm

Standards/Approvals

IEC/EN 60947-2, IEC/EN 60898-1

Tripping Mechanism

Thermal, Electromechanic

Land van herkomst:
CH

ABB S800N Series Miniature Circuit Breaker, 20A Current, 690V Rated AC Voltage - 2CCS893001R0205


This miniature circuit breaker is a three-pole protective device designed to interrupt fault currents in low-voltage electrical installations. It operates across AC and DC systems up to 690 V and uses a combined thermal and electromechanical tripping arrangement to respond to overload and short-circuit conditions. The unit mounts on a DIN rail and provides a resettable I/O actuator with screw-type terminals for conductor connection.

Features and Benefits:


• 36 kA breaking capacity gives strong short-circuit interruption capability
• Type B trip characteristic protects circuits with low inrush currents
• Thermal electromechanical tripping offers overload and instantaneous response
• IP20 and IP40 ratings permit protection in controlled enclosures
• Three-pole configuration enables simultaneous multi-phase disconnection

Applications


• Suitable for industrial DIN-rail distribution boards
• Ideal for motor control with low inrush requirements
• Can be used for AC and DC supply isolation up to 690 V
• Used with panel-mounted control gear requiring screw connections

What method is used to connect conductors to the device?


It employs screw terminals for secure conductor clamping and straightforward wiring.

How is the device mounted within electrical panels?


The breaker is designed for Rapid installation onto standard DIN rails for modular distribution assemblies.

What operational modes does the tripping system provide?


The combined thermal element manages overloads while the electromechanical mechanism delivers an instantaneous trip on high fault currents.

What pole count is available and what does it control?


The device is three-pole, allowing simultaneous interruption of all three phases in a system.