ABB S804S Miniature Circuit Breaker, 4-Pole, 40A, UC-K, 1000 V dc DC, 50 kA Breaking Capacity

Subtotaal (1 eenheid)*

€ 895,37

(excl. BTW)

€ 1.083,40

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Voorradig bij de fabrikant
  • Klaar voor verzending vanaf 04 december 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 895,37

*prijsindicatie

RS-stocknr.:
140-321
Fabrikantnummer:
2CCS864001R1557
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Product Type

Miniature Circuit Breaker

Number of Poles

4

Current Rating

40A

Tripping Characteristics

UC-K

Rated DC Voltage

1000V dc

Breaking Capacity

50kA

Series

S804S

Terminal Type

Screw

IP Rating

IP20

Width

106mm

Standards/Approvals

IEC/EN 60947-2

Depth

82.5mm

Height

95mm

Reset Actuator Type

I/O Actuator

Land van herkomst:
CH

ABB S800S-UC Series Miniature Circuit Breaker, 40A Current, 1000V rated DC voltage - 2CCS864001R1557


This miniature circuit-breaker is designed to protect DC electrical circuits by interrupting fault currents in industrial installations. It operates with a four-pole configuration and a specific tripping characteristic suited to DC applications, providing controlled disconnection where high DC voltages are present. The device is built for panel or system integration in controlled-environment switchgear where finger-safe protection is required.

Features and Benefits:


• 50kA breaking capacity limits fault energy and protects upstream equipment
• UC-K tripping characteristic provides predictable DC fault response
• Screw terminals enable straightforward secure conductor connections
• Reset I/O actuator allows visible manual switching and resetting
• IP20 enclosure rating ensures Basic finger protection in cabinets

Applications


• Suitable for DC solar array string protection up to 1000V
• Used with industrial control gear requiring four-pole isolation
• Ideal for battery-bank distribution systems
• Can be used for protecting motor-drive DC supply rails
• Used for sectionalising DC busbars in commercial installations

What pole configuration does it provide for isolation?


It provides four poles to isolate all conductors simultaneously for complete circuit disconnection.

How does the device perform under high fault currents?


It interrupts fault currents up to 50kA breaking capacity to reduce thermal and mechanical stress on installations.

What Terminal type is used for conductor attachment?


Screw terminals are provided to secure conductors using standard screw-tightening methods.

What operating control is available for manual intervention?


A reset I/O actuator is fitted to permit manual switching and Visual indication of state.

Which standard governs its design for switching applications?


It is designed to meet the requirements of IEC/EN 60947-2 for low-voltage switching devices.