Honeywell GLE Series Nylon Roller Limit Switch, DPST, IP67, Die Cast Zinc Housing, 240V ac, 6A

Subtotaal (1 eenheid)*

€ 161,58

(excl. BTW)

€ 195,51

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 3 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 161,58

*prijsindicatie

RS-stocknr.:
311-2342
Fabrikantnummer:
GLEB06A2B
Fabrikant:
Honeywell
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Honeywell

Product Type

Limit Switch

Actuator Type

Nylon Roller

Contact Configuration

DPST

IP Rating

IP67

Housing Material

Die Cast Zinc

Contact Type

Slow Action

Terminal Type

Screw

Switching Current

6A

Series

GLE

Switching DC Voltage

250V dc

Minimum Operating Temperature

-40°C

Switching AC Voltage

240V ac

Maximum Operating Temperature

85°C

Standards/Approvals

CSA, CCC, CE, UL

Depth

44.2mm

Width

65mm

Length

139mm

Hazardous Area Certification

NO

Mechanical Life

10000000Cycles

Conduit Entry

PG13.5

Operating Force

0.11Nm

Honeywell GLE Series Limit Switch, 6A Switching Current, IP67 - GLEB06A2B


This limit switch is a Compact mechanical device used to detect position changes and actuate control circuits in industrial systems. It is designed for reliable signalling in equipment where a rolling actuator is required and where environmental sealing is essential for continued operation.

Features and Benefits:


• Die-cast zinc housing provides robust environmental protection and durability
• Nylon roller actuator reduces wear and enables smooth mechanical engagement
• IP67 rating permits operation in wet and dusty conditions
• DPST slow-action contacts support straightforward circuit switching
• Rated switching current of 6A allows moderate load control without additional relays
• Mechanical life of 10 million cycles minimises replacement frequency

Applications


• Suitable for end-of-travel detection on conveyor systems
• Ideal for position sensing in packaging machinery
• Used with valve actuation assemblies requiring positive open/close signalling
• Can be used for limit detection in industrial door and gate systems

How is the switch wired into control panels?


Terminations use screw terminals that accept standard control wiring and permit secure connections for AC or DC circuits.

What conduit provisions exist for installation?


A PG13.5 conduit entry is provided to route cable glands or conduit fittings while maintaining enclosure integrity.

What temperatures can the device tolerate during operation?


It operates across a wide thermal range from −40 °C up to 85 °C to suit cold-room or warm-process environments.

How sensitive is the actuator to applied force?


The required operating torque is 0.11 N·m, enabling activation with low mechanical effort while preventing nuisance trips.

Which voltages can the contacts switch?


The contacts are specified for switching at AC 240V and DC 250V to accommodate common control and signalling voltages.

Approvals

UL/ UL listed for Canada

Warning

GLE limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.

Standards

IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.

EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).

IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.

Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.

Gerelateerde Links