Honeywell GLA Series Plunger Limit Switch, DPDT, IP67, Die Cast Zinc Housing, 600V ac, 6A
- RS-stocknr.:
- 223-3218
- Fabrikantnummer:
- GLAC20B
- Fabrikant:
- Honeywell
Subtotaal (1 eenheid)*
€ 250,23
(excl. BTW)
€ 302,78
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Op voorraad
- Plus verzending 5 stuk(s) vanaf 04 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 250,23 |
*prijsindicatie
- RS-stocknr.:
- 223-3218
- Fabrikantnummer:
- GLAC20B
- Fabrikant:
- Honeywell
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Plunger | |
| IP Rating | IP67 | |
| Contact Configuration | DPDT | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Terminal Type | M20 | |
| Switching Current | 6A | |
| Series | GLA | |
| Switching DC Voltage | 250V dc | |
| Minimum Operating Temperature | -25°C | |
| Switching AC Voltage | 600V ac | |
| Maximum Operating Temperature | 85°C | |
| Width | 42mm | |
| Depth | 42mm | |
| Standards/Approvals | CE, CSA, UL, CCC | |
| Length | 145.8mm | |
| Hazardous Area Certification | NO | |
| Conduit Entry | 20 mm | |
| Operating Force | 16N | |
| Mechanical Life | 15000000Cycles | |
| Alles selecteren | ||
|---|---|---|
Merk Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Plunger | ||
IP Rating IP67 | ||
Contact Configuration DPDT | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Terminal Type M20 | ||
Switching Current 6A | ||
Series GLA | ||
Switching DC Voltage 250V dc | ||
Minimum Operating Temperature -25°C | ||
Switching AC Voltage 600V ac | ||
Maximum Operating Temperature 85°C | ||
Width 42mm | ||
Depth 42mm | ||
Standards/Approvals CE, CSA, UL, CCC | ||
Length 145.8mm | ||
Hazardous Area Certification NO | ||
Conduit Entry 20 mm | ||
Operating Force 16N | ||
Mechanical Life 15000000Cycles | ||


Honeywell GLA Series Limit Switch, 20mm Conduit Entry, DPDT Contact Configuration - GLAC20B
This limit switch is a mechanically operated device designed to detect position changes and provide control signals in industrial systems. It uses a plunger actuator to convert physical movement into electrical switching, and is built with a die-cast zinc enclosure and sealed construction for demanding environments. The unit offers double-pole double-throw switching and is suited to applications where snap-action contact behaviour and robustness are required.
Features and Benefits:
• DPDT contact arrangement enables flexible circuit control
• Snap-action contacts deliver Rapid switching response
• Rated for 6A at 600V AC for common industrial loads
• Die-cast zinc housing affords rugged environmental protection
• IP67 sealing permits use in wet and dusty conditions
• Mechanical endurance of 15 million cycles supports long service life
• Snap-action contacts deliver Rapid switching response
• Rated for 6A at 600V AC for common industrial loads
• Die-cast zinc housing affords rugged environmental protection
• IP67 sealing permits use in wet and dusty conditions
• Mechanical endurance of 15 million cycles supports long service life
Applications
• Suitable for conveyor end-of-travel detection in factories
• Ideal for limit sensing on industrial presses and actuators
• Used for position feedback in automated assembly lines
• Can be used for safety interlocks on machine guards
• Suitable for control panels requiring M20 conduit entry
• Ideal for limit sensing on industrial presses and actuators
• Used for position feedback in automated assembly lines
• Can be used for safety interlocks on machine guards
• Suitable for control panels requiring M20 conduit entry
What electrical voltages can it switch for DC circuits?
It can switch DC voltages up to 250V in appropriate circuit configurations.
How does the actuator operate under high-temperature conditions?
The plunger actuator functions across an ambient range from -25°C up to 85°C without compromising switching action.
What conduit connection is provided for wiring?
The unit accepts an M20 conduit entry for standard industrial cable glands and conduit fittings.
Are there recognised approvals for industrial deployment?
It carries CE, CSA, UL and CCC approvals indicating conformity with multiple regional standards.
What type of Terminal Interface does it use?
Termination is provided via an M20-style Terminal arrangement suitable for secure electrical connections.
Approvals
UL/ UL listed for Canada
Warning
GLA limit switches have not been designed as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of the products failing.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
Gerelateerde Links
- Honeywell GLA Series Plunger Limit Switch, DPDT, IP67, Die Cast Zinc Housing, 600 V ac, 6 A
- Honeywell GLA Series Plunger Limit Switch, SPDT, IP67, Die Cast Zinc Housing, 600 V ac, 6 A
- Honeywell GLA Series Plunger Limit Switch, 1 NO/1 NC, IP67, Die Cast Zinc Housing, 600 V ac
- Honeywell GLA Series Roller Lever Limit Switch, DPDT, IP67, Die Cast Zinc Housing, 600 V ac, 6 A
- Honeywell GLA Series Adjustable Roller Lever Limit Switch, DPDT, IP67, Die Cast Zinc Housing, 600 V ac, 6 A
- Honeywell GLA Micro Switch Series Roller Plunger Limit Switch, DPDT, IP67, Zinc Housing, 600V ac, 6A
- Honeywell GLA Series Plunger Limit Switch, 1 NO/1 NC (SPDT), IP67, Die Cast Zinc Housing, 600 V ac, 6 A
- Honeywell GLA Series Roller Plunger Limit Switch, 2 NO/2 NC, IP67, Die Cast Zinc Housing, 600 V ac, 10 A