Siemens Radar Level Probe, PBT Body, ATEX-Rated

Subtotaal (1 eenheid)*

€ 1.188,68

(excl. BTW)

€ 1.438,30

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Informatie over voorraden is momenteel niet toegankelijk
Aantal stuks
Per stuk
1 +€ 1.188,68

*prijsindicatie

RS-stocknr.:
513-2449
Fabrikantnummer:
7ML5430-2BE10
Fabrikant:
Siemens
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Siemens

Device Type

Radar

Body Material

PBT

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+80°C

Maximum Current

20 mA

Maximum Pressure

3bar

Hazardous Area Certification

ATEX

Vrijgesteld

Land van herkomst:
CA

Radar Level Transmitter - SITRANS Probe LR


2 wire loop-powered, intelligent HART ® 5.8 GHz pulsed radar level transmitter
20 metre range as standard
Intrinsically safe ATEX ll 1 G EEx ia IIC T4 approved as standard
Level, and volume measurement
Housing material PBT Valox ® and viewing window PEI Ultem ® - robust; tested to 7 joule impact
LCD alpha numeric display and multi lingual with UV protection
IP67 / IP68 (up to 2 metres, 24 hrs) – Weatherproof
360 degree rotating housing aligns with conduit entry for easy wiring
High signal-to-noise ratio – not affected by drives and power cables
Sonic intelligence - reliable and repeatable measurement
Auto False-Echo suppression – ignores obstructions e.g. stirrers, ladders that can give false readings
100 mm shielded and hermetically sealed uni-construction polypropylene antenna rod – one material; excellent chemical compatibility
Rotating head aligns with conduit for easy wiring
Requires programmer (not supplied) see stock no. 513-2455
Ideal for applications with chemical vapours, temperature gradients, vacuum or pressure, where other level technologies will struggle.
Tank farms, chemical storage, reactor vessels and digesters
CE Marked in compliance with RTTE

Group and Category

II 1 G EEX ia IIC T4

Certificate No.

SIRA 03 ATEX 2142X

Warning

Intrinsically safe ATEX ll 1 G EEx ia IIC T4 approved as standard when used with a suitable Zone 0 safety barrier
CSA certified for Canada & US, FM, FCC
Installation Note:
100 mm shielded rod is only suitable for nozzle heights 100 mm or less. If the nozzle is a greater than 100 mm, this may impair performance of the radar.

Approvals

CSA certified for Canada and US, LROS, FM

Gerelateerde Links