Mobrey Level Switch
The Mobrey ultrasonic liquid level switch with polyphenylene sulphide construction has output type integral SPCO relay (energised when the sensor is wet) and 1-in BSPT dual mount thread. This switch is designed for high or low-level alarm duties to give a voltage-free contact or solid-state transistor output for alarm signalling or as part of a pump control system. It is intended for level detection at a fixed point when liquid fills the gap between the crystals. The supply voltage ranges between 18VAC/DC and 30VAC/DC
Note:
If the liquid to be monitored is flowing, the device should be fitted with the gap inline with the flow. In storage tanks, it should be fitted with the gap vertical unless the liquid is highly aerated when it should be angled.
Note:
If the liquid to be monitored is flowing, the device should be fitted with the gap inline with the flow. In storage tanks, it should be fitted with the gap vertical unless the liquid is highly aerated when it should be angled.
Features and Benefits
Vessel pressure of 5bar (maximum)
Wet switching level detection at a fixed point when liquid fills the gap between the crystals
Switched voltage is 30VDC (maximum)
Suitable for low maintenance applications
High reliability with no moving parts
Not easily subject to fouling and not affected by ambient light conditions
Fitted with three metres of cable
Lightweight
No moving parts
Mounting types are horizontal and vertical
Wet switching level detection at a fixed point when liquid fills the gap between the crystals
Switched voltage is 30VDC (maximum)
Suitable for low maintenance applications
High reliability with no moving parts
Not easily subject to fouling and not affected by ambient light conditions
Fitted with three metres of cable
Lightweight
No moving parts
Mounting types are horizontal and vertical
Applications
Low level alarms in header tanks
Pump control duty in feeder tanks
High and low alarms in storage tanks
Level and pump control in storage tanks
Small or thin wall tanks
Bund level detection
Steering gear oil
Pump control duty in feeder tanks
High and low alarms in storage tanks
Level and pump control in storage tanks
Small or thin wall tanks
Bund level detection
Steering gear oil
Certifications
NEMA 6P (10ft.)/IP66/IP68 (3m)
Specificaties
Kenmerk | Waarde |
Device Type | Gap Sensor Level Alarm Switch |
Mounting Type | Horizontal, Vertical |
Switch Output | Relay |
Body Material | Polyphenylene Sulfide |
Cable Length | 3m |
Minimum Operating Temperature | -20°C |
Maximum Operating Temperature | +70°C |
Maximum Current | 1 A |
Maximum Pressure | 5bar |