Hilscher NetTap 100 2 Port Gateway Server, RS485, RS422, RS232
- RS-stocknr.:
- 162-172
- Fabrikantnummer:
- NT 100-RE-RS+ML
- Fabrikant:
- Hilscher
Subtotaal (1 eenheid)*
€ 752,93
(excl. BTW)
€ 911,05
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Op voorraad
- 10 stuk(s) klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 752,93 |
*prijsindicatie
- RS-stocknr.:
- 162-172
- Fabrikantnummer:
- NT 100-RE-RS+ML
- Fabrikant:
- Hilscher
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Hilscher | |
| Product Type | Gateway Server | |
| System Memory Capacity | 2GB | |
| System Memory Type | SDRAM | |
| Operating System | Windows 7/Higher | |
| Series | NetTap 100 | |
| Media Interfaces | USB | |
| COM Port Type | RS485, RS422, RS232 | |
| Minimum Operating Temperature | 60°C | |
| Minimum Voltage | 18V | |
| Maximum Voltage | 30V | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | UKCA, UL 508, CE Sign | |
| Number of Communication Ports | 2 | |
| Alles selecteren | ||
|---|---|---|
Merk Hilscher | ||
Product Type Gateway Server | ||
System Memory Capacity 2GB | ||
System Memory Type SDRAM | ||
Operating System Windows 7/Higher | ||
Series NetTap 100 | ||
Media Interfaces USB | ||
COM Port Type RS485, RS422, RS232 | ||
Minimum Operating Temperature 60°C | ||
Minimum Voltage 18V | ||
Maximum Voltage 30V | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals UKCA, UL 508, CE Sign | ||
Number of Communication Ports 2 | ||
- Land van herkomst:
- DE
Hilscher Modbus Gateway, 2 Communication Ports, RS485 COM Port Type - NT 100-RE-RS+ML
This Modbus gateway is a Compact protocol-conversion device designed to link Modbus RTU networks to USB-equipped hosts in industrial environments. It provides multiport serial connectivity to integrate devices using RS485, RS422 or RS232 interfaces with Windows 7 and later systems, supporting typical automation and control tasks while operating across standard industrial temperature and supply ranges.
Features and Benefits:
• Supports RS485, RS422 and RS232 ports enabling diverse device connections
• Two communication ports permitting simultaneous links to multiple nodes
• Accepts 18V to 30V supply allowing flexible plant power integration
• Operates from 0°C to 60°C for use in common industrial conditions
• Includes 2 GB SDRAM to manage protocol buffering and throughput
• USB media Interface for straightforward PC or HMI attachment
• Two communication ports permitting simultaneous links to multiple nodes
• Accepts 18V to 30V supply allowing flexible plant power integration
• Operates from 0°C to 60°C for use in common industrial conditions
• Includes 2 GB SDRAM to manage protocol buffering and throughput
• USB media Interface for straightforward PC or HMI attachment
Applications
• Suitable for fieldbus integration between PLCs and SCADA hosts over Modbus RTU
• Ideal for connecting legacy serial sensors to modern Windows-based equipment
• Used with data-loggers requiring USB-based acquisition from RS485 networks
• Can be used for protocol bridging in factory automation test benches
• Used for serial-conversion tasks in remote I/O and device commissioning
• Ideal for connecting legacy serial sensors to modern Windows-based equipment
• Used with data-loggers requiring USB-based acquisition from RS485 networks
• Can be used for protocol bridging in factory automation test benches
• Used for serial-conversion tasks in remote I/O and device commissioning
What host environments are supported for configuration and operation?
It interfaces with Windows 7 and later, using the USB link to present serial connectivity to host software.
How does it cope with volatile data during network bursts?
The 2 GB SDRAM provides buffering capacity to smooth packet handling and reduce transmission stalls.
What electrical supply constraints should be observed?
The unit requires a DC supply within an 18V to 30V window, ensure plant power falls inside this range.
Which standards and approvals does it meet for installation?
It is certified to UKCA, UL508 and CE mark standards relevant to industrial equipment.
How many simultaneous serial channels can be connected?
Two separate communication ports allow concurrent serial links for multi-device integration.
Gerelateerde Links
- Hilscher netTAP 50 1 Port Gateway Server, RS422, RS232, RS485
- Hilscher netTAP 50 1 Port Gateway Server, RS485, RS422, RS232
- Hilscher netTAP NT 50 2 Port Gateway Server, RS232, RS422, RS485
- Hilscher netTAP NT 50 2 Port Gateway Server, RS485, RS422, RS232
- Hilscher netTAP NT 50 2 Port Gateway Server, RS485, RS232, RS422
- Hilscher netTAP 50 1 Port Gateway Server, RS232, RS485, RS422
- Hilscher netTAP 50 1 Port Device Plug Link, RS485, RS232, RS422
- Hilscher netTAP 151 Gateway Server