Fluke 1587 FC Insulation Tester, 50V Min, 1000V Max, 2GΩ Max, CAT III 1000V - RS Calibration
- RS-stocknr.:
- 905-7002
- Fabrikantnummer:
- FLUKE-1587 FC
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 1.156,44
(excl. BTW)
€ 1.399,29
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- 23 stuk(s) klaar voor verzending
- Plus verzending 60 stuk(s) vanaf 06 januari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.156,44 |
*prijsindicatie
- RS-stocknr.:
- 905-7002
- Fabrikantnummer:
- FLUKE-1587 FC
- Fabrikant:
- Fluke
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Model Number p | 1587 FC | |
| Tester Type | Insulation Tester | |
| Maximum Test Voltage | 1000V | |
| Minimum Test Voltage | 50V | |
| Maximum Insulation Resistance Measurement | 2GΩ | |
| Display Type | Backlit LCD | |
| Calibrated | RSCAL | |
| Test Current | 1mA | |
| Battery Life | 1000 h | |
| Battery Type | AA, NEDA 15A | |
| Power Source | Battery | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | +55°C | |
| Safety Category Voltage | 600 V, 1000 V | |
| Safety Category | CAT III 1000 V, CAT IV 600V | |
| Safety Category Level | CAT III, CAT IV | |
| Height | 50mm | |
| Weight | 550g | |
| Length | 203mm | |
| Width | 100mm | |
| Dimensions | 203 x 100 x 50mm | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Model Number p 1587 FC | ||
Tester Type Insulation Tester | ||
Maximum Test Voltage 1000V | ||
Minimum Test Voltage 50V | ||
Maximum Insulation Resistance Measurement 2GΩ | ||
Display Type Backlit LCD | ||
Calibrated RSCAL | ||
Test Current 1mA | ||
Battery Life 1000 h | ||
Battery Type AA, NEDA 15A | ||
Power Source Battery | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature +55°C | ||
Safety Category Voltage 600 V, 1000 V | ||
Safety Category CAT III 1000 V, CAT IV 600V | ||
Safety Category Level CAT III, CAT IV | ||
Height 50mm | ||
Weight 550g | ||
Length 203mm | ||
Width 100mm | ||
Dimensions 203 x 100 x 50mm | ||
Vrijgesteld
- Land van herkomst:
- US
Fluke 1587 FC Insulation Multimeter
The Fluke 1587 FC Insulation Multimeter is the single tool that allows users to perform advanced insulation testing for preventive and PdM tasks. Combining a digital insulation tester with a full-featured, true-rms digital multimeter into a compact, hand-held unit, the 1587 model provides maximum versatility for both troubleshooting and preventative maintenance.
This model is supplied with a remote probe, test leads and alligator clips.
In addition the Fluke 1587 FC Insulation Multimeter adds four powerful new diagnostic functions through the Fluke Connect® Measurements app:
This model is supplied with a remote probe, test leads and alligator clips.
In addition the Fluke 1587 FC Insulation Multimeter adds four powerful new diagnostic functions through the Fluke Connect® Measurements app:
• PI/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster
• Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
• Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
• Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets
• Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
• Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
• Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets
Features and Benefits
• True RMS Digital Multimeter for measuring Voltage and Current
• Auto and Manual ranging
• Selectable filter for accurate measurement of voltage and frequency on motor drives
• User selectable insulation test voltage for many applications
• Remote probe for easy and safe measurement
• Live circuit protection to prevents insulation test if voltage is >30V
• VFD low-pass filter boosts the accuracy of motor-drive tests
• Automatic power-off function saves battery life
• Large digital display with a backlight for easy reading of measurements
• Auto and Manual ranging
• Selectable filter for accurate measurement of voltage and frequency on motor drives
• User selectable insulation test voltage for many applications
• Remote probe for easy and safe measurement
• Live circuit protection to prevents insulation test if voltage is >30V
• VFD low-pass filter boosts the accuracy of motor-drive tests
• Automatic power-off function saves battery life
• Large digital display with a backlight for easy reading of measurements
Fluke 1587 FC Additional Specifications
• VFD low-pass filter for accurate motor drive measurements
• Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V
• Insulation test: 0.01 MΩ to 2.0 GΩ
• Auto-discharge of capacitive voltage
• Insulation test smoothing reading
• Frequency
• Capacitance
• Diode test
• Temperature
• Min/Max
• AC/DC Voltage
• DC Millivolts
• AC/DC Milliamps
• Resistance (0.1 Ω to 50 MΩ)
• Continuity
• K-type thermocouple
• Rugged, utility hard case
• Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V
• Insulation test: 0.01 MΩ to 2.0 GΩ
• Auto-discharge of capacitive voltage
• Insulation test smoothing reading
• Frequency
• Capacitance
• Diode test
• Temperature
• Min/Max
• AC/DC Voltage
• DC Millivolts
• AC/DC Milliamps
• Resistance (0.1 Ω to 50 MΩ)
• Continuity
• K-type thermocouple
• Rugged, utility hard case
Applications
• HVAC systems
• Electrical installations
• Automated industrial equipment
• Medical devices
• IT network
• Electrical installations
• Automated industrial equipment
• Medical devices
• IT network
FAQs
Does the insulation tester have built-in protection against electric shocks?
Yes, this unit features live circuit protection to stop a test if the voltage coming through a sheath is more than 30V.
Do I need to get additional accessories for this tester?
Everything is included with the device. As well as leads, probes and alligator clips, it also comes with a remote probe that helps with measurements in hard-to-reach places.
Yes, this unit features live circuit protection to stop a test if the voltage coming through a sheath is more than 30V.
Do I need to get additional accessories for this tester?
Everything is included with the device. As well as leads, probes and alligator clips, it also comes with a remote probe that helps with measurements in hard-to-reach places.
Supplied with
The Fluke 1587 FC Insulation Multimeter comes with a remote probe, test leads, alligator clips, K-type thermocouple, hard case and user documentation.
Gerelateerde Links
- Fluke 1587 FC Insulation Tester, 50V Min, 1000V Max, 2GΩ Max, CAT III 1000V
- Fluke 1587 FC Insulation Tester, 50V Min, 1000V Max, 2GΩ Max, CAT III 1000V - UKAS Calibration
- Fluke 1587 Insulation Tester, 50V Min, 1000V Max, 2GΩ Max, CAT III 1000V - UKAS Calibration
- Fluke 1587 Insulation Tester, 50V Min, 1000V Max, 2GΩ Max, CAT III 1000V - RS Calibration
- Fluke 1577 Insulation Tester, 500V Min, 1000V Max, 2GΩ Max, CAT III 1000V
- Fluke 1577 Insulation Tester, 500V Min, 1000V Max, 2GΩ Max, CAT III 1000V - RS Calibration
- Fluke 1577 Insulation Tester, 500V Min, 1000V Max, 2GΩ Max, CAT III 1000V - UKAS Calibration
- Fluke 1503 Insulation Tester, 500V Min, 1000V Max, 2GΩ Max, CAT III 600V