Megger MIT515/2 Insulation Resistance Tester, 250 V Min, 5 kV Max, 10 TΩ CAT IV
- RS-stocknr.:
- 718-503
- Fabrikantnummer:
- 1016-079
- Fabrikant:
- Megger
Subtotaal (1 eenheid)*
€ 3.678,00
(excl. BTW)
€ 4.450,38
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Tijdelijk niet op voorraad
- Verzending vanaf 30 november 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 3.678,00 |
*prijsindicatie
- RS-stocknr.:
- 718-503
- Fabrikantnummer:
- 1016-079
- Fabrikant:
- Megger
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Megger | |
| Model Number | MIT515/2 | |
| Product Type | Insulation Tester | |
| Tester Type | Insulation Resistance Tester | |
| Maximum Test Voltage | 5kV | |
| Minimum Test Voltage | 250V | |
| Display Type | Colour Display Screen | |
| Test Current | 3mA | |
| Power Source | Mains Supply | |
| Battery Life | 6h | |
| Battery Type | 10.8 V, Lithium-ion | |
| Insulation Testing Resistance | 10TΩ | |
| Minimum Operating Temperature | -20°C | |
| Safety Category Level | CAT IV | |
| Maximum Operating Temperature | 50°C | |
| Safety Category Voltage | 600V | |
| Standards/Approvals | IEC 61010-031:2008 | |
| Height | 181mm | |
| Width | 285mm | |
| Length | 315mm | |
| Weight | 4.5kg | |
| Alles selecteren | ||
|---|---|---|
Merk Megger | ||
Model Number MIT515/2 | ||
Product Type Insulation Tester | ||
Tester Type Insulation Resistance Tester | ||
Maximum Test Voltage 5kV | ||
Minimum Test Voltage 250V | ||
Display Type Colour Display Screen | ||
Test Current 3mA | ||
Power Source Mains Supply | ||
Battery Life 6h | ||
Battery Type 10.8 V, Lithium-ion | ||
Insulation Testing Resistance 10TΩ | ||
Minimum Operating Temperature -20°C | ||
Safety Category Level CAT IV | ||
Maximum Operating Temperature 50°C | ||
Safety Category Voltage 600V | ||
Standards/Approvals IEC 61010-031:2008 | ||
Height 181mm | ||
Width 285mm | ||
Length 315mm | ||
Weight 4.5kg | ||
- Land van herkomst:
- GB
Robust and accurate insulation testing for motors, transformers, switchgear and cables. The Megger Essential range is designed for engineers who need reliable go/no-go insulation testing without the complexity of onboard storage or Advanced diagnostics. Available in 5 kV (MIT515/2) and 10 kV (MIT1015) models, both testers include Megger's patented technologies to help you work Faster and safer in the field.
Best for: Industrial maintenance engineers, utilities, electrical contractors and OEMs carrying out routine insulation testing on electrical assets.
Best for: Industrial maintenance engineers, utilities, electrical contractors and OEMs carrying out routine insulation testing on electrical assets.
Key features:
Patented PI Predictor™ – Reduces Polarisation Index test time by up to 50%, helping you test more assets in less time.
Patented Re>Act™ technology – Monitors reabsorption current to show when insulation is safe to retest, improving accuracy and reducing the risk of dangerous return voltages.
Stable results in noisy environments – 3 mA noise immunity delivers dependable measurements in typical industrial and distribution applications.
Built for the field – IP65-rated case (lid closed), CAT IV 600 V safety rating, live circuit detection and locking test leads for safe, rugged operation.
Both models offer the same core features and test modes (IR, DAR and PI)
Patented Re>Act™ technology – Monitors reabsorption current to show when insulation is safe to retest, improving accuracy and reducing the risk of dangerous return voltages.
Stable results in noisy environments – 3 mA noise immunity delivers dependable measurements in typical industrial and distribution applications.
Built for the field – IP65-rated case (lid closed), CAT IV 600 V safety rating, live circuit detection and locking test leads for safe, rugged operation.
Both models offer the same core features and test modes (IR, DAR and PI)
the only difference is the maximum test voltage.
Gerelateerde Links
- Megger Insulation Resistance Tester, 250 V Min, 5000 V Max, 30 TΩ CAT IV
- Megger MIT525/2 Insulation Resistance Tester, 250 V Min, 5000 V Max, 10 TΩ CAT IV
- Megger MIT515/2 Insulation Resistance Tester, 250 V Min, 5000 V Max, 10 TΩ CAT IV
- Megger Insulation Resistance Tester, 500 V Min, 10000 V Max, 30 TΩ CAT IV
- Megger Insulation Resistance Tester, 1000 V Min, 15000 V Max, 30 TΩ CAT IV
- Megger MIT1015 Insulation Resistance Tester, 500 V Min, 10000 V Max, 20 TΩ CAT IV
- Megger MIT1525/2 Insulation Resistance Tester, 1000 V Min, 15000 V Max, 30 TΩ CAT IV
- Megger MIT1025/2 Insulation Resistance Tester, 500 V Min, 10000 V Max, 20 TΩ CAT IV