Fluke 1587FC/TPAK/C25 Insulation Multimeter, 50 V Min, 1000 V Max, 2 GΩ CAT III 1000 V, CAT IV 600 V
- RS-stocknr.:
- 458-113
- Fabrikantnummer:
- FLK-1587FC/TPAK/C25
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 1.018,00
(excl. BTW)
€ 1.231,78
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Op voorraad
- 1 stuk(s) klaar voor verzending
- 10 stuk(s) klaar voor verzending vanaf een andere locatie
- Plus verzending 18 stuk(s) vanaf 06 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.018,00 |
*prijsindicatie
Kalibratie-opties
Fluke 1587FC/TPAK/C25 Insulation Multimeter, 50 V Min, 1000 V Max, 2 GΩ CAT III 1000 V, CAT IV 600 V
- Calibration Type:
- RSCAL
- RS-stocknr.
- 458-114
Per stuk
€ 1.087,00
(excl. BTW)
€ 1.315,27
(incl. BTW)
Fluke 1587FC/TPAK/C25 Insulation Multimeter, 50 V Min, 1000 V Max, 2 GΩ CAT III 1000 V, CAT IV 600 V
- Calibration Type:
- UKAS
- RS-stocknr.
- 458-116
Per stuk
€ 1.116,00
(excl. BTW)
€ 1.350,36
(incl. BTW)
- RS-stocknr.:
- 458-113
- Fabrikantnummer:
- FLK-1587FC/TPAK/C25
- Fabrikant:
- Fluke
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Model Number | 1587FC/TPAK/C25 | |
| Product Type | Insulation Tester | |
| Tester Type | Insulation Multimeter | |
| Minimum Test Voltage | 50V | |
| Maximum Test Voltage | 1000V | |
| Display Type | Backlight | |
| Test Current | 1mA | |
| Battery Type | AA | |
| Battery Life | 1000h | |
| Power Source | Battery | |
| Insulation Testing Resistance | 2GΩ | |
| Minimum Operating Temperature | -20°C | |
| Safety Category Voltage | 1000V | |
| Safety Category Level | CAT III 1000 V, CAT IV 600 V | |
| Maximum Operating Temperature | 55°C | |
| Width | 10cm | |
| Standards/Approvals | IEC 610102033, IEC 610101, IEC 60529: IP40, IEC 6132622, IEC 613261, CISPR 11 | |
| Length | 2030000.00mm | |
| Height | 5cm | |
| Weight | 550g | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Model Number 1587FC/TPAK/C25 | ||
Product Type Insulation Tester | ||
Tester Type Insulation Multimeter | ||
Minimum Test Voltage 50V | ||
Maximum Test Voltage 1000V | ||
Display Type Backlight | ||
Test Current 1mA | ||
Battery Type AA | ||
Battery Life 1000h | ||
Power Source Battery | ||
Insulation Testing Resistance 2GΩ | ||
Minimum Operating Temperature -20°C | ||
Safety Category Voltage 1000V | ||
Safety Category Level CAT III 1000 V, CAT IV 600 V | ||
Maximum Operating Temperature 55°C | ||
Width 10cm | ||
Standards/Approvals IEC 610102033, IEC 610101, IEC 60529: IP40, IEC 6132622, IEC 613261, CISPR 11 | ||
Length 2030000.00mm | ||
Height 5cm | ||
Weight 550g | ||
- Land van herkomst:
- US
Fluke Insulation Tester, 1000V Maximum Test Voltage, 2GΩ Insulation Testing Resistance - FLK-1587FC/TPAK/C25
This insulation tester is a handheld, battery-powered instrument that combines insulation resistance measurement with multimeter functions for field diagnostics and preventive maintenance in industrial environments. It is designed for use on live and de-energised equipment, providing insulation resistance up to very high values and selectable test voltages to assess insulation condition under controlled test currents. The unit is suited to technicians working on motors, drives and electrical systems where portable, rugged measurement capability is required.
Features & Benefits
• Insulation range to 2GΩ for detecting high-resistance faults
• Test voltages selectable up to 1000V for versatile inspections
• Nominal test current 1mA to exercise insulation without overload
• Live-circuit inhibit prevents testing if greater than 30V present for safety
• Backlit 6000-count display for clear readings in low light
• Operates on AA batteries delivering around 1000 h of meter use
• Test voltages selectable up to 1000V for versatile inspections
• Nominal test current 1mA to exercise insulation without overload
• Live-circuit inhibit prevents testing if greater than 30V present for safety
• Backlit 6000-count display for clear readings in low light
• Operates on AA batteries delivering around 1000 h of meter use
Applications
• Suitable for motor winding insulation assessment with VFDs
• Ideal for commissioning and preventive maintenance checks
• Used for troubleshooting insulation degradation on switchgear
• Can be used for asset baseline recording in industrial plants
• Suitable for on-site field testing of cables and installations
• Ideal for commissioning and preventive maintenance checks
• Used for troubleshooting insulation degradation on switchgear
• Can be used for asset baseline recording in industrial plants
• Suitable for on-site field testing of cables and installations
How does the instrument handle capacitive loads during insulation tests?
It is operable with capacitive loads up to 1 μF and auto-discharges capacitive voltage rapidly, with discharge time less than 0.5 s for C = 1 μF or less.
What environmental limits apply for onsite use?
The unit functions between -20 °C and 55 °C and can be stored between -40 °C and 60 °C
humidity limits vary with temperature up to 95% non‑condensing at 10 °C–30 °C.
What protection and safety categories does it meet?
It is rated for CAT III 1000V and CAT IV 600V measurement categories and meets IEC safety standards including IEC 61010 variants.
How is data handling supported for trend analysis and storage?
When used with compatible wireless tools and software it enables timed ratio tests, trend graphs, memory storage and temperature compensation via a measurements app.
What accessory options improve field usability?
Accessories include remote probe, test leads, crocodile clips, a magnetic hanger option and a soft case for site work.
Gerelateerde Links
- Fluke 1587FC/TPAK/C25 Insulation Multimeter, 50 V Min, 1000 V Max, 2 GΩ CAT III 1000 V, CAT IV 600 V
- Fluke 179/TPAK/C25 Digital Multimeter, 1000 V Max CAT III 1000 V, CAT IV 600 V
- Fluke 1587 FC Insulation Tester, 50 V Min, 1000 V Max, 2 GΩ CAT IV, CAT III
- UNI-T UT511 Insulation Resistance Tester, 1000 V Max, 10 GΩ CAT III, CAT II
- UNI-T UT505B Insulation Resistance Tester, 1000 V Max, 200 GΩ CAT IV, CAT III
- Fluke 1507 Insulation Tester, 50 V Min, 1000 V Max, 10 GΩ CAT III, CAT IV
- Fluke 1577 Insulation Tester, 500 V Min, 1000 V Max, 2 GΩ CAT III, CAT IV
- Extech MG310 Insulation Tester, 250 V Min, 1000 V Max, 5.5 GΩ CAT III

