Alpha Wire Ecogen Ecowire Series Black 0.75 mm² Hook Up Wire, 18 AWG, 16, 305 m, Modified Polyphenylene Ether, 6715
- RS-stocknr.:
- 741-8133
- Fabrikantnummer:
- 6715 BL001
- Fabrikant:
- Alpha Wire
Subtotaal (1 rol van 305 meter)*
€ 302,00
(excl. BTW)
€ 365,42
(incl. BTW)
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 302,00 | € 0,99 |
*prijsindicatie
- RS-stocknr.:
- 741-8133
- Fabrikantnummer:
- 6715 BL001
- Fabrikant:
- Alpha Wire
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Alpha Wire | |
| Product Type | Hook Up Wire | |
| Cross Sectional Area | 0.75mm² | |
| Jacket Colour | Black | |
| American Wire Gauge | 18AWG | |
| Core Strands | 16 | |
| Cable Length | 305m | |
| Voltage | 600V | |
| Outside Diameter | 0.067in | |
| Maximum Operating Temperature | 105°C | |
| Conductor Material | Copper | |
| Standards/Approvals | CE, CSA, UL | |
| Cable Type | Hookup | |
| Jacket Material | Modified Polyphenylene Ether | |
| Sub Type | EcoWire | |
| Minimum Operating Temperature | -40°C | |
| Fire Behaviour | Flame Retardant | |
| Series | Ecogen Ecowire | |
| Alles selecteren | ||
|---|---|---|
Merk Alpha Wire | ||
Product Type Hook Up Wire | ||
Cross Sectional Area 0.75mm² | ||
Jacket Colour Black | ||
American Wire Gauge 18AWG | ||
Core Strands 16 | ||
Cable Length 305m | ||
Voltage 600V | ||
Outside Diameter 0.067in | ||
Maximum Operating Temperature 105°C | ||
Conductor Material Copper | ||
Standards/Approvals CE, CSA, UL | ||
Cable Type Hookup | ||
Jacket Material Modified Polyphenylene Ether | ||
Sub Type EcoWire | ||
Minimum Operating Temperature -40°C | ||
Fire Behaviour Flame Retardant | ||
Series Ecogen Ecowire | ||
Belden Ecogen Ecowire Series Hook Up Wire, 0.75mm² Cross Sectional Area, Black Jacket - 6715 BL001
This hook‑up wire provides insulated single‑core conductor suitable for internal wiring in control panels and equipment. It is designed for use where flexible copper conductors are needed within electrical, electronic and mechanical assemblies, offering a balance of thermal performance and flame‑retardant behaviour for demanding installation environments.
Features & Benefits
• 16‑strand conductor offers enhanced flexibility for routing
• 0.75mm² cross‑sectional area supports common signal and power duties
• 600V rating enables higher‑voltage internal wiring applications
• Modified polyphenylene ether jacket resists chemicals and ageing
• Rated to 105°C for elevated‑temperature operation
• VW‑1 and IEC 60332‑2 flame behaviour reduces flame propagation
• 0.75mm² cross‑sectional area supports common signal and power duties
• 600V rating enables higher‑voltage internal wiring applications
• Modified polyphenylene ether jacket resists chemicals and ageing
• Rated to 105°C for elevated‑temperature operation
• VW‑1 and IEC 60332‑2 flame behaviour reduces flame propagation
**Applications**
• Suitable for internal wiring of automation control cabinets
• Ideal for interconnections in electronic test rigs and instruments
• Used for wiring within electro‑mechanical assemblies and drives
• Can be used for branch circuits in industrial machinery harnesses
• Ideal for interconnections in electronic test rigs and instruments
• Used for wiring within electro‑mechanical assemblies and drives
• Can be used for branch circuits in industrial machinery harnesses
What conductor material is used and how does it affect performance?
The conductor is copper, which provides low electrical resistance and good conductivity for carrying signals and power in Compact cross‑sections.
How does the jacket composition influence long‑term use?
The modified polyphenylene ether jacket offers dimensional stability and resistance to many industrial contaminants, supporting longevity in enclosure and harness applications.
Which flame and heat behaviours are relevant to installation safety?
It meets a VW‑1 flame test and IEC 60332‑2 rating, and operates up to 105°C, helping to limit flame spread and tolerate higher operating temperatures in confined spaces.
What approvals support acceptance in professional projects?
The cable conforms to recognised international standards and approvals for wiring products, facilitating specification in regulated installations.
Standards
UL AWM 11028 VW-1, CSA AWM I A/B FT1, RoHS/RoHS2 Compliant, IEC 60332-2 Flame Behavior, REACH Compliant, CE Compliant
Gerelateerde Links
- Alpha Wire, 16, Modified Polyphenylene Ether, 6715 DB001
- Alpha Wire, 16, Modified Polyphenylene Ether, 6715 DB005
- Alpha Wire, 16, Modified Polyphenylene Ether, 6715 BR001
- Alpha Wire, 16, Modified Polyphenylene Ether, 6715 YL001
- Alpha Wire, 16, Modified Polyphenylene Ether, 6715 RD005
- Alpha Wire, 16, Modified Polyphenylene Ether, 6715 RD001
- Alpha Wire, 16, Modified Polyphenylene Ether, 6715 GR001
- Alpha Wire, 16, Modified Polyphenylene Ether, 6715 BK005
