Lapp Brown 0.5 mm² Hook Up Wire, 20 AWG, 16/32 mm, 100m, PVC Insulation, 4510031
- RS-stocknr.:
- 724-4323
- Fabrikantnummer:
- 4510031
- Fabrikant:
- Lapp
Subtotaal (1 rol van 100 meter)*
€ 41,02
(excl. BTW)
€ 49,63
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- 11 stuk(s) klaar voor verzending
- 14 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 41,02 | € 0,41 |
*prijsindicatie
- RS-stocknr.:
- 724-4323
- Fabrikantnummer:
- 4510031
- Fabrikant:
- Lapp
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Lapp | |
| Cross Sectional Area | 0.5 mm² | |
| Sheath Colour | Brown | |
| Cable Shape | Single Core | |
| American Wire Gauge | 20 AWG | |
| Core Strands | 16/32 mm | |
| Length | 100m | |
| Insulation Material | PVC | |
| European Harmonised Code | H05V-K | |
| Outer Diameter | 2.1mm | |
| Voltage Rating | 500 V | |
| Maximum Operating Temperature | +80°C | |
| CPR Certification | Eca | |
| Minimum Operating Temperature | -30°C | |
| Conductor Material | Copper | |
| Size of Strands | 32 AWG | |
| Number of Strands | 16 | |
| Alles selecteren | ||
|---|---|---|
Merk Lapp | ||
Cross Sectional Area 0.5 mm² | ||
Sheath Colour Brown | ||
Cable Shape Single Core | ||
American Wire Gauge 20 AWG | ||
Core Strands 16/32 mm | ||
Length 100m | ||
Insulation Material PVC | ||
European Harmonised Code H05V-K | ||
Outer Diameter 2.1mm | ||
Voltage Rating 500 V | ||
Maximum Operating Temperature +80°C | ||
CPR Certification Eca | ||
Minimum Operating Temperature -30°C | ||
Conductor Material Copper | ||
Size of Strands 32 AWG | ||
Number of Strands 16 | ||
Lapp Single Core Cable - H05V-K
From Lapp, this single-core H05V-K hook-up wire is ideal for fixed installations in power and control applications. The cable features a fine-wired copper conductor with PVC based core insulation, and is flame retardant.
The H05V-K hook-up wire has European HAR cable type certification.
Features and Benefits
Bare copper wire conductor according to VDE 0295 class 5; HD 383 S2
Nominal working voltage 300/500V
Minimum bending radius 6 x cable diameter
Flame-retardant according to IEC 60332-1-2
Operating Temperature when Fixed: -40°C to +80°C
Applications
These versatile hook-up wires are typically used in the internal wiring of devices, or for protected installations in and on lighting equipment. This hook-up wire is often used in the following applications:
Power Management
Industrial Machinery
Medical Equipment
Frequently Asked Questions
Can this wire be used outdoors?
Wires are designed to be used in indoor systems, however, the wide temperature operation resistance may allow for a short period of time outdoor operation.
Which wire types are a better choice, stranded or solid?
Both stranded and solid wire have the same resistance properties but stranded wire guarantee an extra flexibility, resistance to bending and are generally easier to install than solid cables.
The H05V-K hook-up wire has European HAR cable type certification.
Features and Benefits
Bare copper wire conductor according to VDE 0295 class 5; HD 383 S2
Nominal working voltage 300/500V
Minimum bending radius 6 x cable diameter
Flame-retardant according to IEC 60332-1-2
Operating Temperature when Fixed: -40°C to +80°C
Applications
These versatile hook-up wires are typically used in the internal wiring of devices, or for protected installations in and on lighting equipment. This hook-up wire is often used in the following applications:
Power Management
Industrial Machinery
Medical Equipment
Frequently Asked Questions
Can this wire be used outdoors?
Wires are designed to be used in indoor systems, however, the wide temperature operation resistance may allow for a short period of time outdoor operation.
Which wire types are a better choice, stranded or solid?
Both stranded and solid wire have the same resistance properties but stranded wire guarantee an extra flexibility, resistance to bending and are generally easier to install than solid cables.
Note
These are supplied in boxes not reels.
Standards
EN 50525-2-31, IEC 60332-1-2
Gerelateerde Links
- Lapp ÖLFLEX HEAT Series Brown 0.5 mm² Hook Up Wire, 20 AWG, 19/0.25 mm, 100m, Silicone Insulation, 48003
- Lapp OLFLEX HEAT Series Brown 0.5 mm² Hook Up Wire, 20 AWG, 100m, Cross Linked Polyolefin Insulation, 1232003
- Lapp Brown 1.5 mm² Hook Up Wire, 15 AWG, 100m, PVC Insulation, 4160403
- Lapp Brown 0.75 mm² Hook Up Wire, 18 AWG, 100m, PVC Insulation, 4160203
- Lapp Brown 0.52 mm² Hook Up Wire, 22 AWG, 100m, PVC Insulation, 4160103
- Lapp Brown 1 mm² Hook Up Wire, 17 AWG, 100m, PVC Insulation, 4160303
- Lapp Brown 2.5 mm² Hook Up Wire, 13 AWG, 100m, PVC Insulation, 4160503
- Lapp ÖLFLEX® Series Brown 4 mm² Hook Up Wire, 100m, PVC Insulation, 4520033
