Eaton 160A Fuse Holder, 3P-Pole for 135 x 715 mm, 690V

Subtotaal (1 eenheid)*

€ 262,17

(excl. BTW)

€ 317,23

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Voorradig bij de fabrikant
  • Klaar voor verzending vanaf 24 augustus 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 262,17

*prijsindicatie

RS-stocknr.:
261-888
Fabrikantnummer:
EBV0033SV0
Fabrikant:
Eaton
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Eaton

Product Type

Fuse Holder

Current Rating

160A

Voltage

690V

Number of Poles

3

Compatible Fuse Size

135 x 715 mm

Standards/Approvals

IEC/EN 60947-1 IEC 60947-3

Series

Bussmann

Vrijgesteld

Land van herkomst:
PL

Eaton Fuse Holder, 160A Current Rating, 690V Voltage - EBV0033SV0


This fuse holder is a three-pole device designed to accommodate NH-format fuses for use in industrial electrical systems. It provides a secure base for high-current protective elements and is intended for installation where three-phase protection and disconnection are required. The product is suitable for environments operating at elevated voltages and is constructed to conform with recognised switchgear standards.

Features & Benefits


• Rated for 160A continuous current handling
• Supports system voltages up to 690V enabling high-voltage use
• Accepts 135 x 715 mm NH fuse elements for high-current protection
• Three-pole configuration allows simultaneous phase switching
• Complies with IEC/EN 60947-1 and IEC 60947-3 for switchgear integration

**Applications**


• Suitable for three-phase distribution boards in industrial plants
• Ideal for coordination with NH fuses in motor control centres
• Used with high-current feeders in automation panels
• Can be used for protection in electrical distribution switchgear

What fuse format does it accept and how does that affect selection?


It is compatible with NH fuses sized 135 x 715 mm, so selection should match that physical form factor and the intended breaking capacity of the circuit.

How should it be specified for a 160A circuit installation?


Specify the base for 160A continuous current and ensure mating fuse and upstream protection are coordinated for thermal and short-circuit performance.

What is the pole configuration and why does that matter for three-phase systems?


The unit uses a three-pole arrangement, allowing all three phases to be isolated or switched simultaneously for safer maintenance and clearer fault segregation.