HellermannTyton Connectivity RJ45SPC6A, 5 m Ethernet Cable, White Screened
- RS-stocknr.:
- 695-329
- Fabrikantnummer:
- RJ45SPC6A-05.0M/WH
- Fabrikant:
- HellermannTyton Connectivity
Subtotaal (1 eenheid)*
€ 20,43
(excl. BTW)
€ 24,72
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Voorradig bij de fabrikant
- Klaar voor verzending vanaf 25 september 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 20,43 |
*prijsindicatie
- RS-stocknr.:
- 695-329
- Fabrikantnummer:
- RJ45SPC6A-05.0M/WH
- Fabrikant:
- HellermannTyton Connectivity
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | HellermannTyton Connectivity | |
| Series | RJ45SPC6A | |
| Product Type | Ethernet Cable | |
| Cable Length | 5m | |
| Sub Type | Ethernet Cable | |
| Screened/Unscreened | Screened | |
| Jacket Colour | White | |
| Minimum Operating Temperature | -20°C | |
| Conductor Type | Stranded | |
| Maximum Operating Temperature | 50°C | |
| Fire Behaviour | Halogen Free | |
| Standards/Approvals | ISO/IEC 11801 | |
| Number of Cores | 8 | |
| Conductor Material | Copper | |
| Outside Diameter | 4.7mm | |
| Alles selecteren | ||
|---|---|---|
Merk HellermannTyton Connectivity | ||
Series RJ45SPC6A | ||
Product Type Ethernet Cable | ||
Cable Length 5m | ||
Sub Type Ethernet Cable | ||
Screened/Unscreened Screened | ||
Jacket Colour White | ||
Minimum Operating Temperature -20°C | ||
Conductor Type Stranded | ||
Maximum Operating Temperature 50°C | ||
Fire Behaviour Halogen Free | ||
Standards/Approvals ISO/IEC 11801 | ||
Number of Cores 8 | ||
Conductor Material Copper | ||
Outside Diameter 4.7mm | ||
- Land van herkomst:
- GB
HellermannTyton Connectivity RJ45SPC6A Series Patch Lead, 5m Cable Length, White Jacket - RJ45SPC6A-05.0M/WH
This patch lead provides a screened Ethernet connection for data networks, designed for environments where reduced halogen emissions and controlled smoke are required. It uses a stranded copper conductor configuration with eight cores to carry Cat6a-level signals across a fixed run length, and is specified to operate reliably in a wide temperature range found in many industrial and commercial installations.
Features and Benefits:
• Screened construction reduces electromagnetic interference for cleaner signals
• Low Smoke Zero Halogen jacket limits toxic emissions during fire
• Stranded copper conductors enhance flexibility for frequent re-routing
• RoHS compliance minimises restricted substance content for safe disposal
• Operates from -20°C to 50°C for varied ambient conditions
• Low Smoke Zero Halogen jacket limits toxic emissions during fire
• Stranded copper conductors enhance flexibility for frequent re-routing
• RoHS compliance minimises restricted substance content for safe disposal
• Operates from -20°C to 50°C for varied ambient conditions
Applications
• Suitable for structured cabling in office network cabinets
• Ideal for server racks requiring screened connections
• Used for patching in comms rooms with LSZH requirements
• Can be used for linking active network equipment on site
• Useful in installations demanding halogen-free materials
• Ideal for server racks requiring screened connections
• Used for patching in comms rooms with LSZH requirements
• Can be used for linking active network equipment on site
• Useful in installations demanding halogen-free materials
What is the conductor arrangement and how does it affect cable handling?
The cable contains eight copper conductors in a stranded format, which reduces stiffness and improves bendability compared with solid cores, simplifying routing through trays and around equipment.
How does the cables screening affect installation near power cabling?
The screened design provides a barrier against external electromagnetic fields, lowering crosstalk risks when routed adjacent to power circuits or other noisy sources.
What jacket properties assist emergency response and building safety?
The low smoke zero halogen jacket material emits reduced smoke density and negligible halogenated gases when exposed to fire, aiding visibility and reducing toxic fume hazards.
Which environmental limits should be observed during use?
The lead is specified for continuous operation between -20°C and 50°C, so it should not be deployed in locations that exceed these temperature boundaries.
Gerelateerde Links
- HellermannTyton Connectivity RJ45SPC6A, 0.5 m Ethernet Cable, White Screened
- HellermannTyton Connectivity RJ45SPC6A, 20 m Ethernet Cable, White Screened
- HellermannTyton Connectivity RJ45SPC6A, 3 m Ethernet Cable, White Screened
- HellermannTyton Connectivity RJ45SPC6A, 0.3 m Ethernet Cable, White Screened
- HellermannTyton Connectivity RJ45SPC6A, 13 m Ethernet Cable, White Screened
- HellermannTyton Connectivity RJ45SPC6A, 10 m Ethernet Cable, White Screened
- HellermannTyton Connectivity RJ45SPC6A, 6 m Ethernet Cable, White Screened
- HellermannTyton Connectivity RJ45SPC6A, 7 m Ethernet Cable, White Screened
