Belden 1885ELW, 1000 m Cat7 Cable, Orange Low Smoke Zero Halogen Sheath
- RS-stocknr.:
- 644-582
- Fabrikantnummer:
- 1885ELW.011000
- Fabrikant:
- Belden
Subtotaal (1 rol van 1000 meter)*
€ 2.474,07
(excl. BTW)
€ 2.993,62
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Voorradig bij de fabrikant
- Klaar voor verzending vanaf 20 juli 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 2.474,07 | € 2,474 |
*prijsindicatie
- RS-stocknr.:
- 644-582
- Fabrikantnummer:
- 1885ELW.011000
- Fabrikant:
- Belden
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Belden | |
| Series | 1885ELW | |
| Product Type | Cat7 Cable | |
| Cable Length | 1000m | |
| Sub Type | Cat7 Cable | |
| Jacket Material | Low Smoke Zero Halogen | |
| Jacket Colour | Orange | |
| Minimum Operating Temperature | 30°C | |
| Conductor Type | Solid | |
| Maximum Operating Temperature | 60°C | |
| Fire Behaviour | IEC 60332-1-2 | |
| Standards/Approvals | REACH, EU CE, IEC 60332-1-2, RoHS | |
| Voltage | 72V | |
| Outside Diameter | 7.6mm | |
| Number of Cores | 4 | |
| Conductor Material | Bare Copper | |
| Alles selecteren | ||
|---|---|---|
Merk Belden | ||
Series 1885ELW | ||
Product Type Cat7 Cable | ||
Cable Length 1000m | ||
Sub Type Cat7 Cable | ||
Jacket Material Low Smoke Zero Halogen | ||
Jacket Colour Orange | ||
Minimum Operating Temperature 30°C | ||
Conductor Type Solid | ||
Maximum Operating Temperature 60°C | ||
Fire Behaviour IEC 60332-1-2 | ||
Standards/Approvals REACH, EU CE, IEC 60332-1-2, RoHS | ||
Voltage 72V | ||
Outside Diameter 7.6mm | ||
Number of Cores 4 | ||
Conductor Material Bare Copper | ||
- Land van herkomst:
- HU
Belden 1885ELW Series Thin Ethernet Cable, 1000m Cable Length, Orange Jacket - 1885ELW.011000
This thin Ethernet cable is designed for high-performance network connectivity where space and safety considerations matter. It serves as a Compact Cat7 solution for installations requiring a narrow-profile conduit, enhanced fire-behaviour characteristics and a visible jacket for easy identification in complex cabling environments.
Features and Benefits:
• 1000 m reel length reduces installation joins and downtime
• Low Smoke Zero Halogen jacket limits toxic emissions in fires
• Bare solid copper conductors deliver consistent signal integrity
• IEC60332-1-2 fire performance supports staged fire-safety planning
• 72V rating permits compatibility with common low-voltage systems
• 4-core design simplifies pairing for Cat7 link assemblies
• Low Smoke Zero Halogen jacket limits toxic emissions in fires
• Bare solid copper conductors deliver consistent signal integrity
• IEC60332-1-2 fire performance supports staged fire-safety planning
• 72V rating permits compatibility with common low-voltage systems
• 4-core design simplifies pairing for Cat7 link assemblies
Applications
• Suitable for data centres requiring identifiable Orange cabling
• Ideal for industrial automation networks with confined routing
• Used for structured building cabling in commercial installations
• Can be used for indoor/outdoor runs where solid conductors are preferred
• Ideal for industrial automation networks with confined routing
• Used for structured building cabling in commercial installations
• Can be used for indoor/outdoor runs where solid conductors are preferred
What conductor construction does this cable use and why does it matter?
It uses solid bare copper conductors, which provide stable impedance and are preferable for permanent runs where low insertion loss and long-term electrical consistency are required.
How does the jacket material affect safety and environment?
The Low Smoke Zero Halogen composition reduces toxic and corrosive gases during combustion, improving evacuation conditions and limiting damage to sensitive equipment.
What temperature range can it reliably operate within?
The cable is specified to function between -30°C and 60°C, covering typical indoor and protected outdoor environments without performance degradation.
Which regulatory or conformity marks are associated with the product?
It conforms to REACH and RoHS requirements and carries CE marking, indicating adherence to applicable EU chemical and electrical standards.
Gerelateerde Links
- Belden Unterminated, 1000 m Cat7 Cable, Blue Low Smoke Zero Halogen Sheath
- Belden 1885ENH, 500 m Cat7 Cable, Orange Low Smoke Zero Halogen Sheath
- Belden 1885ENH, 1000 m Cat7 Cable, Orange Low Smoke Zero Halogen Sheath
- Belden Unterminated, 500 m Cat7 Cable, Grey Low Smoke Zero Halogen Sheath
- Belden 1888ELW, 500 m Cat7 Cable, Blue Low Smoke Zero Halogen Sheath
- Belden 74005NH, 500 m Cat7 Cable, Blue Low Smoke Zero Halogen Sheath
- Belden Unterminated, 100 m Cat7 Cable, Grey Low Smoke Zero Halogen Sheath
- Belden 74004NH, 500 m Cat7 Cable, Black Low Smoke Zero Halogen Sheath