Belden, 500 m Cat6a Power Cable Assembly, Blue Straight to Unterminated Low Smoke Zero Halogen Sheath, U/FTP
- RS-stocknr.:
- 631-589
- Fabrikantnummer:
- 10GXV03.06500
- Fabrikant:
- Belden
Subtotaal (1 rol van 500 meter)*
€ 839,10
(excl. BTW)
€ 1.015,31
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Tijdelijk niet op voorraad
- Verzending vanaf 21 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 839,10 | € 1,678 |
*prijsindicatie
- RS-stocknr.:
- 631-589
- Fabrikantnummer:
- 10GXV03.06500
- Fabrikant:
- Belden
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Belden | |
| Product Type | Power Cable Assembly | |
| Cable Length | 500m | |
| LAN Category | Cat6a | |
| Shield Type | U/FTP | |
| Connector Type A | Straight | |
| Connector Type B | Unterminated | |
| Jacket Colour | Blue | |
| Jacket Material | Low Smoke Zero Halogen | |
| Standards/Approvals | CE, IEC 62821, ISO/IEC 11801-1, EU | |
| Series | 10GXV03 | |
| Voltage | 72V | |
| Alles selecteren | ||
|---|---|---|
Merk Belden | ||
Product Type Power Cable Assembly | ||
Cable Length 500m | ||
LAN Category Cat6a | ||
Shield Type U/FTP | ||
Connector Type A Straight | ||
Connector Type B Unterminated | ||
Jacket Colour Blue | ||
Jacket Material Low Smoke Zero Halogen | ||
Standards/Approvals CE, IEC 62821, ISO/IEC 11801-1, EU | ||
Series 10GXV03 | ||
Voltage 72V | ||
- Land van herkomst:
- HU
Belden Power Cable Assembly, 500m Cable Length, Blue Jacket - 10GXV03.06500
This power cable assembly provides a long-distance, shielded power link for industrial control and automation systems. It is designed to carry low-voltage power in installations where reduced-toxicity emissions and enhanced signal integrity are required, and is suited to environments that demand compliance with European and international wiring standards.
Features and Benefits:
• 500m length enables extended runs without splices
• U/FTP shielding reduces crosstalk and EMI susceptibility
• Low smoke zero halogen jacket limits toxic gases in fires
• Blue sheath aids Visual identification in cable routes
• Straight connector to unterminated end allows field termination
• Rated for 72V operation for low-voltage power distribution
• U/FTP shielding reduces crosstalk and EMI susceptibility
• Low smoke zero halogen jacket limits toxic gases in fires
• Blue sheath aids Visual identification in cable routes
• Straight connector to unterminated end allows field termination
• Rated for 72V operation for low-voltage power distribution
Applications
• Suitable for long cable runs between control panels and equipment
• Ideal for power supply to distributed automation nodes
• Used with industrial sensors and actuators requiring shielded feed
• Can be used for temporary or permanent installations in factories
• Suitable for installations needing a blue LSZH Visual standard
• Ideal for power supply to distributed automation nodes
• Used with industrial sensors and actuators requiring shielded feed
• Can be used for temporary or permanent installations in factories
• Suitable for installations needing a blue LSZH Visual standard
What jacket properties affect routing through containment?
The halogen-free, low-smoke outer material has flexibility and abrasion resistance suitable for cable trays and conduits while reducing harmful emissions during combustion.
How does the shielding influence earthing practices?
The U/FTP construction concentrates shielding per core pair and typically requires a single-point or recommended equipotential bonding at termination to control EMI and earth-loop currents.
What termination options are possible at the unterminated end?
Field termination can be performed with crimped lugs, soldered connections, or factory-style connectorisation compatible with 72V-rated terminals, following accepted strip and shield termination methods.
Which approvals are relevant for specification and procurement?
The cable meets European and international standards referenced for safety and performance, aligning it with common regulatory criteria for industrial deployments.
Gerelateerde Links
- Belden, 500 m Cat6a Power Cable Assembly, Yellow Straight to Unterminated Low Smoke Zero Halogen Sheath, S/FTP
- Belden, 500 m Cat6a Power Cable Assembly, Blue Straight to Unterminated Low Smoke Zero Halogen Sheath, F/FTP
- Belden, 500 m Cat6a Power Cable Assembly, Purple Straight to Unterminated Low Smoke Zero Halogen Sheath, F/FTP
- Belden, 500 m Cat6a Power Cable Assembly, Grey Straight to Unterminated Low Smoke Zero Halogen Sheath, S/FTP
- Belden, 500 m Cat6a Power Cable Assembly, Purple Straight to Unterminated Low Smoke Zero Halogen Sheath, S/FTP
- Belden, 500 m Cat6a Power Cable Assembly, Blue Straight to Unterminated Low Smoke Zero Halogen Sheath, S/FTP
- Belden, 100 m Cat6a Power Cable Assembly, Grey Straight to Unterminated Low Smoke Zero Halogen Sheath, S/FTP
- Weidmüller Cat6a, 200 mm, Grey, S/FTP Low Smoke Zero Halogen Sheath