Duracell Procell Intense 1.5 V Alkaline D Battery

Subtotaal (1 doos van 10 eenheden)*

€ 30,37

(excl. BTW)

€ 36,75

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Dozen
Per Doos
Per stuk*
1 +€ 30,37€ 3,037

*prijsindicatie

RS-stocknr.:
212-4958
Fabrikantnummer:
5000394137011
Fabrikant:
Duracell Procell
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Duracell Procell

Series

Intense

Product Type

D Battery

Battery Size

D

Chemistry

Alkaline

Nominal Voltage

1.5V

IEC Code

LR20

Battery Capacity

1.56Ah

Termination Type

Flat

Standards/Approvals

ANSI, IEC

Height

61.5mm

Diameter

34.20mm

Weight

140g

Vrijgesteld

Duracell Intense Series D Battery, 1.5V Nominal Voltage, 1.56Ah Battery Capacity - 5000394137011


This D battery is an alkaline zinc-manganese dioxide cell designed for devices requiring a sustained 1.5V output. It is intended for use where steady power delivery and long service life are needed across a range of ambient temperatures. The cell meets international standards for safety and quality and is terminated with a flat contact for straightforward installation in cylindrical housings.

Features and Benefits:


• 1.56 Ah capacity delivers extended run time for continuous loads
• 136mΩ AC impedance reduces internal losses at high frequency
• Operates down to -20°C for low-temperature performance
• Flat termination simplifies insertion and replacement
• 140g mass provides stable contact in heavy-duty applications

Applications


• Suitable for sanitiser dispenser power modules
• Ideal for automatic odouriser units in facilities
• Used with paper-towel dispenser drive systems
• Can be used for medical device battery compartments
• Suitable for handheld torches in prolonged use

What storage environment preserves charge and lifespan?


Store cells in a cool, dry, ventilated place between 5°C and 30°C.

How does delivered capacity vary with load?


Capacity depends on applied current, temperature and cut-off voltage, so service life decreases at higher currents.

Which standards govern safety and environmental compliance?


The cell conforms to IEC 60086-5, ANSI C18.1M Part 2 and the EU Battery Directive.

What electrical behaviour should be expected at room temperature?


Typical voltage is 1.5V at +20°C and nominal capacity is measured at a 50mA continuous discharge with a 0.8V cut-off.

Gerelateerde Links